The FastHub 116T LEDs facilitate troubleshooting during ongoing operation. Table 4-1 displays the potential problem symptoms, possible causes, and corrective actions.

Table 4-1 Troubleshooting

Symptom Possible Cause Corrective Action(s)
Power LED does not come on Power switch off Turn on switch

Power cord not connected Plug in both ends of power cord

Fuse blown Replace fuse. If problem reoccurs, contact Cisco Systems or your authorized reseller

Other Contact Cisco Systems or your authorized reseller
Link LED does not come on No cable inserted Insert both ends of cable into a device

Device(s) not powered Ensure both devices have power

Wrong cable type Verify cable selection (crossover vs. non-crossover)

Bad cable Replace cable with known good one
Disabled LED blinks Device at other end malfunction-ing Investigate device at other end of cable from the Disabling FastHub 116T port

Bad cable Replace cable with known good one