Preparing to Install the Cisco 2500 Series Access Server
This chapter describes the tasks you must perform before you begin to install the Cisco 2500 series access server. It includes the following sections:
Follow these guidelines to ensure general safety:
Maintaining Safety with Electricity
Follow these guidelines when working on equipment powered by electricity.
Preventing Electrostatic Discharge Damage
Electrostatic discharge (ESD) can damage equipment and impair electrical circuitry. It occurs when electronic components are improperly handled and can result in complete or intermittent failures.
Always follow ESD-prevention procedures when removing and replacing components. Ensure that the chassis is electrically connected to earth ground. Wear an ESD-preventive wrist strap, ensuring that it makes good skin contact. Connect the clip to an unpainted surface of the chassis frame to safely channel unwanted ESD voltages to ground. To properly guard against ESD damage and shocks, the wrist strap and cord must operate effectively. If no wrist strap is available, ground yourself by touching the metal part of the chassis.
This section describes the requirements your site must meet for safe installation and operation of your system. Ensure that your site is properly prepared before beginning installation.
The access server can be placed on a desktop or mounted in a rack or on a wall.
The location of individual chassis and the layout of your equipment rack or wiring room are extremely important for proper system operation. Equipment placed too close together, inadequate ventilation, and inaccessible panels can cause system malfunctions and shutdowns, and can make system maintenance difficult.
When planning your site layout and equipment locations, keep in mind the precautions described in the next section, "Preventive Site Configuration" to help avoid equipment failures and reduce the possibility of environmentally caused shutdowns. If you are currently experiencing shutdowns or unusually high errors with your existing equipment, these precautions may help you isolate the cause of failures and prevent future problems.
The following precautions will help you plan an acceptable operating environment for your access server and will help you avoid environmentally caused equipment failures:
The following tips will help you plan an acceptable equipment rack configuration:
Check the power at your site to ensure that you are receiving "clean" power (free of spikes and noise). Install a power conditioner if necessary.
The access server power supply includes the following features:
The Installation Checklist lists the procedures for initial hardware installation of a new access server. Make a copy of this checklist and mark the entries as you complete each procedure. Include a copy of the checklist for each system in your Site Log. (See the following section, "Creating a Site Log.")
The Site Log provides a record of all actions relevant to the system. Keep it near the chassis where anyone who performs tasks has access to it. Use the Installation Checklist (see the previous section "Installation Checklist") to verify steps in the installation and maintenance of your system. Site Log entries might include the following:
When setting up your access server, consider distance limitations and potential electromagnetic interference (EMI) as defined by the Electronic Industries Association (EIA).
Following are the distance limitation specifications for Ethernet, Token Ring, and serial interfaces.
The distance limitations for the IEEE 802.3 (10Base5 coaxial cable) specification indicate a maximum segment distance of 1,640 feet (500 m) at a transmission rate of 10 megabits per second (Mbps).
The distance limitations for Ethernet 10BaseT indicate a maximum segment distance of 328 feet (100 m); Ethernet 10Base2 has a maximum segment distance of 656 feet (200 m).
The distance limitations for the IEEE 802.5 specification indicate a maximum segment distance of 328 feet (100 m) at a transmission rate of 4 or 16 Mbps for unshielded twisted-pair (UTP) cable. The distance limitation when using shielded twisted-pair (STP) cabling is 1,640 feet (500 m).
As with all signaling systems, EIA/TIA-232 signals can travel a limited distance at any given bit rate; generally, the slower the data rate, the greater the distance. Table 2-1 shows the standard relationship between baud rate and maximum distance.
Table 2-1 : EIA/TIA-232 Speed and Distance Limitations
The use of balanced drivers allows EIA/TIA-449 signals to travel greater distances than the
Table 2-2 : EIA/TIA-449 Speed and Distance Limitations
Console and Auxiliary Port Considerations
This section discusses important cabling information that must be considered before you connect the terminals or modems to console and auxiliary ports. The console port and the auxiliary port are used to provide access to the system either locally or remotely.
Each access server system includes an EIA/TIA-232 (RJ-45) console asynchronous serial port. This port connects to a terminal using an RJ-45 cable and an RJ-45-to-DB-25 adapter. Depending on the cable and the adapter used, this port will appear as a data terminal equipment (DTE) or data communications equipment (DCE) device at the end of the cable. To connect to a console terminal, use an RJ-45 rollover cable with a female DTE connector (labeled "Terminal") for connection to the console port. For detailed information on installing the console terminal see the section "Connecting to the Console Port" in the chapter "Installing the Cisco 2500 Series Access Server.")
The appendix "Cable Specifications" lists the pinout for the console port. The default parameters for the console port are 9600 baud, 8 data bits, no parity, and 2 stop bits. The console port does not support hardware flow control or modem control.
An EIA/TIA-232 (RJ-45) auxiliary asynchronous serial port is included on all access servers. This port can connect to a modem for remote maintenance, or terminal services. Use an RJ-45 rollover cable with a male modem (MMOD) adapter (labeled "Modem") for this connection. For detailed information on connecting devices to the auxiliary port, see the section "Connecting a Modem to the Auxiliary Port" in the chapter "Installing the Cisco 2500 Series Access Server." See the appendix "Cable Specifications" for the pinout for this auxiliary port.
Network Connection Considerations
This sections describes important cabling information that must be considered before making your network connections. The Ethernet or Token Ring ports are used to connect to a LAN; the synchronous serial ports are used to connect to a WAN; and the asynchronous ports are used to provide remote access to the access server.
The Ethernet port is located on the left of the rear panel of the access server. The port is labeled AUI. Use an Ethernet transceiver to connect the access server directly to the network.
You can use the following equipment to connect to the Ethernet AUI port:
The connection to the AUI port can be attached using one of two connector types, as follows:
The Token Ring port is located on the left of the rear panel and is labeled TOKEN RING. Use a standard 9pin Token Ring lobe cable (not supplied) to connect the access server directly to a media attachment unit (MAU).
Synchronous Serial Connections
The synchronous serial interface ports are located on the rear of the access server to the right of the Ethernet or Token Ring connector. The ports are labeled SERIAL 0 and SERIAL 1 (from left to right when facing the rear panel). The serial ports are 60-pin, D-type connectors. All serial interfaces (except the EIA-530) can be configured as DTE or DCE, depending on the attached cable. All DTE serial ports require that external clocking be provided by a channel service unit/data service unit (CSU/DSU) or other DCE device.
You must use a special serial cable to connect the access server to a modem or CSU/DSU. This cable is available from Cisco and is usually ordered with the system. The cable uses a DB-60 connector on the chassis end. See the appendix "Cable Specifications" for cable pinouts. For ordering information, contact a customer service representative.
Asynchronous Serial Connections
The asynchronous serial ports use one or two 68-pin connectors located on the far left of the rear panel. Each of the connectors provides eight asynchronous ports. The lower port is labeled ASYNC 1--8, and the upper port is labeled ASYNC 9--16. Breakout cables that divide into eight RJ-45 connectors each are connected to the asynchronous connectors.
RJ-45-to-DB-25 adapters are used to connect to external devices such as modems, printers, or terminals. RJ-45-to-DB-25 adapters are available from Cisco for either DCE or DTE connections. See the appendix "Cable Specifications" to select the correct adapter, and for pinouts for the RJ-45-to-DB-25 adapters.
Do not unpack the access server until you are ready to install it. If the final installation site will not be ready for some time, keep the chassis in its shipping container to prevent accidental damage. When you have determined where you want the access server installed, proceed with the unpacking.
The access server, cables, UniverCD or printed publications, and any optional equipment you ordered might be shipped in more than one container. When you unpack each shipping container, check the packing list to ensure that you received all of the following items:
Inspect all items for shipping damage. If anything appears to be damaged, or if you encounter problems when installing or configuring your system, contact a customer service representative.
Copyright 1988-1996 © Cisco Systems Inc.
"Safety Recommendations" earlier in this chapter to avoid damage to equipment. Damage from static discharge can cause immediate or intermittent equipment failure.
Installation checklist for site_____________________________________________
Access server name__________________________________________________________
Task
Verified by
Date
Installation checklist copied
Background information placed in Site Log
Site power voltages verified
Installation site prepower check completed
Required tools available
Additional equipment available
Access server received
Optional UniverCD received or ordered, printed documentation received
Chassis components verified
Initial electrical connections established
ASCII terminal attached to console port, or modem attached to console port (for remote configuration)
Signal distance limits verified
Startup sequence steps completed
Initial system operation verified
Software image verified
Data Rate (Baud)
Distance (Feet)
Distance (Meters)
2400
200
60
4800
100
30
9600
50
15
19,200
50
15
38,400
50
15
57,600
25
7.6
115,200
12
3.7
EIA/TIA232 standard. Table 2-2 lists the standard relationship between baud rate and maximum distance for EIA/TIA-449 signals. These limits are also valid for V.35 and X.21.
Data Rate (Baud)
Distance (Feet)
Distance (Meters)
2400
4,100
1,250
4800
2,050
625
9600
1,025
312
19200
513
156
38400
256
78
56000
102
31
T1
50
15