This appendix lists the pinouts for ports on the supervisor engine module and other modules, and for some interface cable connectors that connect modules to the external network. All pins not specifically listed are not connected.
Following is a list of the signal summaries contained in this appendix:
The console port on the supervisor engine module is an EIA/TIA-232, data communications equipment (DCE), DB-25 receptacle. Both data set ready (DSR) and data carrier detect (DCD) are active when the system is running. The Request To Send (RTS) signal tracks the state of the Clear To Send (CTS) input. The console port does not support modem control or hardware flow control. Table D-1 and Table D-2 list the signals used on this port for all types of supervisor engine modules used in the Catalyst 5000.
Table D-1 : Supervisor Engine Module with RJ-45 and Media-Independent Interface (MII) Connectors
Pin | Signal | Direction | Description |
---|---|---|---|
1 | GND | Ground | |
2 | RxD | ---> | Receive data |
3 | TxD | <--- | Transmit Data |
4 | CTS | <--- | Clear to send |
5 | RTS | ---> | Request-to-send |
7 | GND | Ground | |
8 | DTR | ---> | Data terminal ready |
20 | DCD | <--- | Data carrier detect |
Table D-2 : Supervisor Engine (MMF and SMF) DB-25 Console Port Signals
Pin | Signal | Direction | Description |
---|---|---|---|
1 | GND | Ground | |
2 | RxD | Input | Receive Data |
3 | TxD | Output | Transmit Data |
4 | CTS | Input | Clear-to-Send |
5 | RTS | Output | Request-to-Send |
7 | GND | Ground | |
8 | DTR | Output | Data Terminal Ready |
18 | GND | Ground |
Fast Ethernet MII Connector Signals
Most Ethernet transceivers require a transceiver cable to connect an Ethernet transceiver to the supervisor engine module and Ethernet switching module Ethernet ports. Some unshielded twisted-pair (10BaseT) transceivers are compact enough to connect directly to the Ethernet module ports without impeding other connections. For descriptions of Ethernet transceivers, connectors, and cables, refer to the section "Setting Up Ethernet Connection Equipment" in the chapter "Installation Overview."
Table D-3 lists the signals for the supervisor engine module 40-pin MII Fast Ethernet connector.
Table D-3 : Supervisor Engine Module 40-Pin MII Fast Ethernet Connector Signals
Pin | Signal | |
---|---|---|
1 | +5V | |
2 | MDIO | |
3 | MDC | |
4 | RxD<3> | |
5 | RxD<2> | |
6 | RxD<1> | |
7 | RxD<0> | |
8 | Rx_DV | |
9 | Rx_Clk | |
10 | Rx_Er | |
11 | Tx_Er | |
12 | Tx_Clk | |
13 | Tx_En | |
14 | TxD<0> | |
15 | TxD<1> | |
16 | TxD<2> | |
17 | TxD<3> | |
18 | Col | |
19 | CRS | |
20 | +5V | |
21 | +5V | |
22 | Common | |
23 | Common | |
24 | Common | |
25 | Common | |
26 | Common | |
27 | Common | |
28 | Common | |
29 | Common | |
30 | Common | |
31 | Common | |
32 | Common | |
33 | Common | |
34 | Common | |
35 | Common | |
36 | Common | |
37 | Common | |
38 | Common | |
39 | Common | |
40 | +5V |
Table D-4 lists the signals for the supervisor engine module RJ-45 Fast Ethernet 100BaseTX MDI X port and Fast Ethernet 100BaseTX module ports.
Table D-4 : Supervisor Engine Module 100BaseTX MDI X Port Signals
Pin | Signal | Direction | Description |
---|---|---|---|
1 | RxD+ | <--- | Receive data + |
2 | RxD-- | <--- | Receive data -- |
3 | TxD+ | ---> | Transmit Data + |
4 | NC | No connection | |
5 | NC | No connection | |
6 | TxD-- | ---> | Transmit Data -- |
7 | NC | No connection | |
8 | NC | No connection |
Table D-5 lists the signals for the 10BaseT 24-port switching module RJ-21 Telco Ethernet connector port.
Pin |
Signal |
Direction |
Description |
Ethernet
Port No. |
---|---|---|---|---|
1 | RxD (+ or --) | <--- | Receive Data | 1 |
2 | TxD (+ or --) | ---> | Transmit Data | 1 |
26 | RxD (+ or --) | <--- | Receive Data | 1 |
27 | TxD (+ or --) | ---> | Transmit Data | 1 |
3 | RxD (+ or --) | <--- | Receive Data | 2 |
4 | TxD (+ or --) | ---> | Transmit Data | 2 |
28 | RxD (+ or --) | <--- | Receive Data | 2 |
29 | TxD (+ or --) | ---> | Transmit Data | 2 |
5 | RxD (+ or --) | <--- | Receive Data | 3 |
6 | TxD (+ or --) | ---> | Transmit Data | 3 |
30 | RxD (+ or --) | <--- | Receive Data | 3 |
31 | TxD (+ or --) | ---> | Transmit Data | 3 |
7 | RxD (+ or --) | <--- | Receive Data | 4 |
8 | TxD (+ or --) | ---> | Transmit Data | 4 |
32 | RxD (+ or --) | <--- | Receive Data | 4 |
33 | TxD (+ or --) | ---> | Transmit Data | 4 |
9 | RxD (+ or --) | <--- | Receive Data | 5 |
10 | TxD (+ or --) | ---> | Transmit Data | 5 |
34 | RxD (+ or --) | <--- | Receive Data | 5 |
35 | TxD (+ or --) | ---> | Transmit Data | 5 |
11 | RxD (+ or --) | <--- | Receive Data | 6 |
12 | TxD (+ or --) | ---> | Transmit Data | 6 |
36 | RxD (+ or --) | <--- | Receive Data | 6 |
37 | TxD (+ or --) | ---> | Transmit Data | 6 |
13 | RxD (+ or --) | <--- | Receive Data | 7 |
14 | TxD (+ or --) | ---> | Transmit Data | 7 |
38 | RxD (+ or --) | <--- | Receive Data | 7 |
39 | TxD (+ or --) | ---> | Transmit Data | 7 |
15 | RxD (+ or --) | <--- | Receive Data | 8 |
16 | TxD (+ or --) | ---> | Transmit Data | 8 |
40 | RxD (+ or --) | <--- | Receive Data | 8 |
41 | TxD (+ or --) | ---> | Transmit Data | 8 |
17 | RxD (+ or --) | <--- | Receive Data | 9 |
18 | TxD (+ or --) | ---> | Transmit Data | 9 |
42 | RxD (+ or --) | <--- | Receive Data | 9 |
43 | TxD (+ or --) | ---> | Transmit Data | 9 |
19 | RxD (+ or --) | <--- | Receive Data | 10 |
20 | TxD (+ or --) | ---> | Transmit Data | 10 |
44 | RxD (+ or --) | <--- | Receive Data | 10 |
45 | TxD (+ or --) | ---> | Transmit Data | 10 |
21 | RxD (+ or --) | <--- | Receive Data | 11 |
22 | TxD (+ or --) | ---> | Transmit Data | 11 |
46 | RxD (+ or --) | <--- | Receive Data | 11 |
47 | TxD (+ or --) | ---> | Transmit Data | 11 |
23 | RxD (+ or --) | <--- | Receive Data | 12 |
24 | TxD (+ or --) | ---> | Transmit Data | 12 |
48 | RxD (+ or --) | <--- | Receive Data | 12 |
49 | TxD (+ or --) | ---> | Transmit Data | 12 |
25 | (Not Used) | |||
50 | (Not Used) |
Table D-6 lists the signals for the ATM LAN Emulation (UTP) Module RJ-45 connector.
Table D-6 : ATM LAN Emulation Module (UTP) RJ-45 Port Pinouts
Pin | Signal | Direction | Description |
---|---|---|---|
1 | TxD+ | ---> | Transmit data + |
2 | TxD-- | ---> | Transmit data -- |
3 | NC | No connection | |
4 | NC | No connection | |
5 | NC | No connection | |
6 | NC | No connection | |
7 | RxD+ | <--- | Receive data + |
8 | RxD-- | <--- | Receive data -- |
FDDI Optical Bypass Switch Signals
Table D-7 lists the signal descriptions for the mini-DIN optical bypass switch available on the FDDI modules. The mini-DIN-to-DIN adapter cable connector allows connection to an optical bypass switch that uses a DIN connector.
Table D-7 : Optical Bypass Switch Pinouts
Pin | Description |
---|---|
1 | +5V to secondary switch |
2 | +5V to primary switch |
3 | Ground to enable primary switch |
4 | Ground to enable secondary switch |
5 | Sense circuit---1 kohm to +5 V |
6 | Ground---Sense circuit return |
CDDI Transmit and Receive Connector Pinouts
Table D-8 lists the signal descriptions for straight-through connectors and Table D-9 lists the signal descriptions for cross-connect connectors used with CDDI modules.
Table D-8 : CDDI Straight-Through Connector Pinouts
Pin | Signal | Direction | Signal | Pin |
---|---|---|---|---|
1 | TxD | ---> | RxD | 1 |
2 | TxD | ---> | RxD | 2 |
3 | NC | No connection | NC | 3 |
4 | NC | No connection | NC | 4 |
5 | NC | No connection | NC | 5 |
6 | NC | No connection | NC | 6 |
7 | RxD | <--- | TxD | 7 |
8 | RxD | <--- | TxD | 8 |
Table D-9 : CDDI Cross-Connect Connector Pinouts
Pin | Signal | Direction | Signal | Pin |
---|---|---|---|---|
1 | RxD | <--- | TxD | 8 |
2 | RxD | <--- | TxD | 7 |
3 | NC | No connection | NC | 6 |
4 | NC | No connection | NC | 5 |
5 | NC | No connection | NC | 4 |
6 | NC | No connection | NC | 3 |
7 | TxD | ---> | RxD | 2 |
8 | TxD | ---> | RxD | 1 |
![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() |
Copyright 1988-1996 © Cisco Systems Inc.