Stratacom StrataView Network MIBs

--
--  Stratacom StrataView Network MIBs
--
--      $RCSfile: SV+Network.mib,v $
--      $Revision: 1.1.4.2.1 $
--      $Date: 1996/04/29 07:28:57 $
--
--      Consolidated MIB for event, node, filters, rtc and rtm
--
--

STRATACOM-STRATAVIEW-SVPLUS-MIB
DEFINITIONS ::= BEGIN

IMPORTS
  Gauge     FROM RFC1155-SMI
  DisplayString    FROM RFC1213-MIB
  OBJECT-TYPE    FROM RFC-1212;

internet    OBJECT IDENTIFIER ::= { iso(1) org(3) dod(6) 1 }
private    OBJECT IDENTIFIER ::= { internet 4 }
enterprises    OBJECT IDENTIFIER ::= { private 1 }

stratacom    OBJECT IDENTIFIER ::= { enterprises 351 }
svplus    OBJECT IDENTIFIER ::= { stratacom 1 }
svnode    OBJECT IDENTIFIER ::= { stratacom 2 }
-- connSvc    OBJECT IDENTIFIER ::= { stratacom 3 }
-- portSvc    OBJECT IDENTIFIER ::= { stratacom 4 }
rtm    OBJECT IDENTIFIER ::= { stratacom 120 }
-- strmErrors    OBJECT IDENTIFIER ::= { stratacom 910 }
-- StrataView Plus Generated events. Added br HJ and Sridhar
strataviewEvents    OBJECT IDENTIFIER ::= { stratacom 920 }
 

--
--  Note that Object identifiers { svplus 1 } through { svplus 10 } 
--  have been depricated.
--

controlGroup    OBJECT IDENTIFIER ::= { svplus 11 }
logGroup    OBJECT IDENTIFIER ::= { svplus 12 }
networkGroup    OBJECT IDENTIFIER ::= { svplus 13 }
nodeGroup    OBJECT IDENTIFIER ::= { svplus 14 }

svNodeGroup            OBJECT IDENTIFIER ::= { svnode 1 }
packetGroup            OBJECT IDENTIFIER ::= { svnode 2 }
circuitGroup            OBJECT IDENTIFIER ::= { svnode 3 }
frpGroup            OBJECT IDENTIFIER ::= { svnode 4 }
connGroup            OBJECT IDENTIFIER ::= { svnode 5 }
realTimeCountersGroup    OBJECT IDENTIFIER ::= { svnode 6 }
trapsConfig     OBJECT IDENTIFIER ::= { rtm 1 }


Active    ::= INTEGER  {
      inactive  (1),
      active  (2)
      }

--  Values currently used for "severity" in log records and
--  TRAP filters are "Clear", "Info", "Minor", "Major", and
--  "Updt" (for update).  Others may be used in the future.
--
Severity  ::= DisplayString (SIZE (0..5))

nodeGrpName      OBJECT-TYPE
  SYNTAX    DisplayString (SIZE(0..10))
  ACCESS    read-only
  STATUS    mandatory
  DESCRIPTION    "IPX node name."
  ::=    { svNodeGroup 1 }

nodeGrpNetName      OBJECT-TYPE
  SYNTAX    DisplayString (SIZE(0..10))
  ACCESS    read-only
  STATUS    mandatory
  DESCRIPTION    "IPX network name."
  ::=    { svNodeGroup 2 }

nodeGrpAlarmState      OBJECT-TYPE
  SYNTAX    INTEGER  { 
        clear  (1),
        minor  (2),
        major  (3),
        unreachable  (5)
        }
  ACCESS    read-only
  STATUS    mandatory
  DESCRIPTION    "Node Alarm State. Only low 6 bits are
      valid."
  ::=    { svNodeGroup 3 }

nodeGrpGateway      OBJECT-TYPE
  SYNTAX    INTEGER  {
        not-a-gateway  (1),
        gateway  (2)
        }
  ACCESS    read-only
  STATUS    mandatory
  DESCRIPTION    "Is this node acting as a gateway?"

  ::=    { svNodeGroup 4 }

nodeGrpActive      OBJECT-TYPE
  SYNTAX    Active
  ACCESS    read-only
  STATUS    mandatory
  DESCRIPTION    "Active state of this Node."
  ::=    { svNodeGroup 5 }

nodeGrpPlatform      OBJECT-TYPE
  SYNTAX    INTEGER  {
        ipx-platform  (1),
        bpx-platform  (2)
        axis-platform  (3)
        }
  ACCESS    read-only
  STATUS    mandatory
  DESCRIPTION    "Platform type."
  ::=    { svNodeGroup 6 }

nodeGrpRelease      OBJECT-TYPE
  SYNTAX    DisplayString (SIZE(0..10))
  ACCESS    read-only
  STATUS    mandatory
  DESCRIPTION    "StrataView Plus release revision."
  ::=    { svNodeGroup 7 }

nodeFsIncRate      OBJECT-TYPE
  SYNTAX    INTEGER
  ACCESS    read-only
  STATUS    mandatory
  DESCRIPTION    "FRP Foresight increase rate."
  ::=    { svNodeGroup 8 }

nodeFsDecRate      OBJECT-TYPE
  SYNTAX    INTEGER
  ACCESS    read-only
  STATUS    mandatory
  DESCRIPTION    "FRP forsight normal decrease rate."
  ::=    { svNodeGroup 9 }

nodeFsFastRate      OBJECT-TYPE
  SYNTAX    INTEGER
  ACCESS    read-only
  STATUS    mandatory
  DESCRIPTION    "FRP forsight fast decrease rate."
  ::=    { svNodeGroup 10 }

nodeRstTimeout      OBJECT-TYPE
  SYNTAX    INTEGER
  ACCESS    read-only
  STATUS    mandatory
  DESCRIPTION    "Timeout for resetting PVC rate to QIR."
  ::=    { svNodeGroup 11 }

alarmTrapSequenceNumber      OBJECT-TYPE
  SYNTAX    INTEGER
  ACCESS    read-only
  STATUS    mandatory
  DESCRIPTION    "The Sequence Number of the last trap
       generated on the SNMP Proxy"
  ::=    { svNodeGroup 12 }


-----------------------------------------------------------------------

--  Packet Group
-----------------------------------------------------------------------

-----------------------------------------------------------------------
--  Packet Line Table has been deleted and replaced by the 
--      Trunk Table.   
-----------------------------------------------------------------------
--pktLineTable      OBJECT-TYPE
--  SYNTAX    SEQUENCE OF PktLineEntry
--  ACCESS    not-accessible
--  STATUS    mandatory
--  DESCRIPTION    "The table of Packet Lines."
--  ::=    { packetGroup 1 }


-----------------------------------------------------------------------
--  Trunk Table
-----------------------------------------------------------------------

trunkTable      OBJECT-TYPE
  SYNTAX    SEQUENCE OF TrunkEntry
  ACCESS    not-accessible
  STATUS    mandatory
  DESCRIPTION    "The table of Trunk Lines."
  ::=    { packetGroup 2 }

trunkEntry      OBJECT-TYPE
  SYNTAX    TrunkEntry
  ACCESS    not-accessible
  STATUS    mandatory
  DESCRIPTION    "An entry in the Trunk table."
  INDEX    { trunkLocalSlot, trunkLocalPort }
  ::=    { trunkTable 1 }

TrunkEntry  ::=  SEQUENCE {
  trunkLocalSlot      INTEGER,
  trunkLocalPort      INTEGER,
  trunkLocalLine      INTEGER,
  trunkCardType      INTEGER,
  trunkInterface      INTEGER,
  trunkLineLoad      INTEGER,
  trunkRemNodeId      INTEGER,
  trunkRemLineNumber      INTEGER,
  trunkRemSlot      INTEGER,
  trunkRemPort      INTEGER,
  trunkAlarmState      INTEGER,
  trunkComment      DisplayString,
  trunkActive      Active,
  trunkStatus      INTEGER,
  trunkStatReserve      INTEGER,
  trunkBurstyDataBQDepth      INTEGER,
  trunkBurstyDataBQEfcnThreshold      INTEGER,
  trunkClpHighDropThreshold      INTEGER,
  trunkClpLowDropThreshold      INTEGER
}

trunkLocalSlot      OBJECT-TYPE
  SYNTAX    INTEGER
  ACCESS    read-only
  STATUS    mandatory
  DESCRIPTION    "Local Slot Number.  These are numbered
      starting at 1."
  ::=    { trunkEntry 1 }

trunkLocalPort      OBJECT-TYPE

  SYNTAX    INTEGER
  ACCESS    read-only
  STATUS    mandatory
  DESCRIPTION    "Local Port Number.  These are numbered
       starting at 1."
  ::=    { trunkEntry 2 }

trunkLocalLine      OBJECT-TYPE
  SYNTAX    INTEGER
  ACCESS    read-only
  STATUS    mandatory
  DESCRIPTION    "Local Line Number.  These are numbered
       starting at 1."
  ::=    { trunkEntry 3 }

trunkCardType      OBJECT-TYPE
  SYNTAX    INTEGER  { txr(3),
          bni(4),
          ntc(22),
          atm(31),
          ait(34),
          bni-t3(103),
          bni-e3(104)
        }
  ACCESS    read-only
  STATUS    mandatory
  DESCRIPTION    "Type of the card supporting the trunk             line.
      The card type is dependant on the value
      of nodePlatform.

      Additional types may exist with future 
      hardware."
  ::=    { trunkEntry 4 }

trunkInterface      OBJECT-TYPE
  SYNTAX    INTEGER  { unknown (1),
          t1-d4   (2),
          t1-esf  (3),
          e1-30   (4),
          e1-31   (5),
          e1-32   (6),
          subrate (7),
          atm     (8) }
  ACCESS    read-only
  STATUS    mandatory
  DESCRIPTION    "Trunk Line Interface Type. Indicates
       the format of the packet line."
  ::=    { trunkEntry 5 }

trunkLineLoad      OBJECT-TYPE
  SYNTAX    INTEGER
  ACCESS    read-only
  STATUS    mandatory
  DESCRIPTION    "Line Load in packets per second."
  ::=    { trunkEntry 6 }

trunkRemNodeId      OBJECT-TYPE
  SYNTAX    INTEGER
  ACCESS    read-only
  STATUS    mandatory
  DESCRIPTION    "Remote StrataView Node ID."
  ::=    { trunkEntry 7 }

trunkRemLineNumber      OBJECT-TYPE
  SYNTAX    INTEGER

  ACCESS    read-only
  STATUS    mandatory
  DESCRIPTION    "Remote Line Number."
  ::=    { trunkEntry 8 }

trunkRemSlot      OBJECT-TYPE
  SYNTAX    INTEGER
  ACCESS    read-only
  STATUS    mandatory
  DESCRIPTION    "Remote Slot Number."
  ::=    { trunkEntry 9 }

trunkRemPort      OBJECT-TYPE
  SYNTAX    INTEGER
  ACCESS    read-only
  STATUS    mandatory
  DESCRIPTION    "Remote Port Number."
  ::=    { trunkEntry 10 }

trunkAlarmState      OBJECT-TYPE
  SYNTAX    INTEGER  {
       clear  (1),
        info  (2),
        minor  (3),
        major  (4) 
        }
  ACCESS    read-only
  STATUS    mandatory
  DESCRIPTION    "Trunk Line Alarm State."
  ::=    { trunkEntry 11 }

trunkComment      OBJECT-TYPE
  SYNTAX    DisplayString (SIZE(0..20))
  ACCESS    read-only
  STATUS    mandatory
  DESCRIPTION    "StrataView user entered comment field used to
      further qualify the trunk line."
  ::=    { trunkEntry 12 }

trunkActive      OBJECT-TYPE
  SYNTAX    Active
  ACCESS    read-only
  STATUS    mandatory
  DESCRIPTION    "Active State."
  ::=    { trunkEntry 13 }

trunkStatus      OBJECT-TYPE
  SYNTAX    INTEGER  {
        inactive(1),
        clear(2),
        fail(3),
        down(4)
        }
  ACCESS    read-only
  STATUS    mandatory
  DESCRIPTION    "Trunk line status."
  ::=    { trunkEntry 14 }

trunkStatReserve      OBJECT-TYPE
  SYNTAX    INTEGER
  ACCESS    read-only
  STATUS    mandatory
  DESCRIPTION    "Trunk Line statistical reserve field."
  ::=    { trunkEntry 15 }


trunkBurstyDataBQDepth      OBJECT-TYPE
  SYNTAX    INTEGER
  ACCESS    read-only
  STATUS    mandatory
  DESCRIPTION    "Trunk Line bursty data B queue depth."
  ::=    { trunkEntry 16 }

trunkBurstyDataBQEfcnThreshold      OBJECT-TYPE
  SYNTAX    INTEGER
  ACCESS    read-only
  STATUS    mandatory
  DESCRIPTION    "Trunk Line bursty data B queue
       EFCN/FFCI threshold."
  ::=    { trunkEntry 17 }

trunkClpHighDropThreshold      OBJECT-TYPE
  SYNTAX    INTEGER
  ACCESS    read-only
  STATUS    mandatory
  DESCRIPTION    "Trunk Line CLP high 
      dropping threshold."
  ::=    { trunkEntry 18 }

trunkClpLowDropThreshold      OBJECT-TYPE
  SYNTAX    INTEGER
  ACCESS    read-only
  STATUS    mandatory
  DESCRIPTION    "Trunk Line CLP low dropping threshold."
  ::=    { trunkEntry 19 }

-----------------------------------------------------------------------
--  Circuit Group
-----------------------------------------------------------------------

-----------------------------------------------------------------------
--  Circuit Line Table
-----------------------------------------------------------------------
cirLineTable      OBJECT-TYPE
  SYNTAX    SEQUENCE OF CirLineEntry
  ACCESS    not-accessible
  STATUS    mandatory
  DESCRIPTION    "The table of Circuit Lines."
  ::=    { circuitGroup 1 }

cirLineEntry      OBJECT-TYPE
  SYNTAX    CirLineEntry
  ACCESS    not-accessible
  STATUS    mandatory
  DESCRIPTION    "An entry in the Circuit Line table."
  INDEX    { cirLineLineNumber }
  ::=    { cirLineTable 1 }

CirLineEntry  ::=  SEQUENCE {
  cirLineLineNumber    INTEGER,
  cirLineCardType    INTEGER,
  cirLineInterface    INTEGER,
  cirLineComment    DisplayString,
  cirLineActive    Active,
  cirLineStatus    INTEGER
}

cirLineLineNumber      OBJECT-TYPE
  SYNTAX    INTEGER
  ACCESS    read-only
  STATUS    mandatory

  DESCRIPTION    "Circuit Line Number."
  ::=    { cirLineEntry 3 }

cirLineCardType      OBJECT-TYPE
  SYNTAX    INTEGER  { 
        txr (3),
        cip(21),
        cdp(29) 
        }
  ACCESS    read-only
  STATUS    mandatory
  DESCRIPTION    "Circuit Card Type."
  ::=    { cirLineEntry 4 }

cirLineInterface      OBJECT-TYPE
  SYNTAX    INTEGER  { 
        unknown (1),
          t1 (2),
          e1(3) 
        }
  ACCESS    read-only
  STATUS    mandatory
  DESCRIPTION    "Circuit Line Interface Type.  
      Indicates the format of the circuit line."
  ::=    { cirLineEntry 5 }

cirLineComment      OBJECT-TYPE
  SYNTAX    DisplayString (SIZE(0..22))
  ACCESS    read-only
  STATUS    mandatory
  DESCRIPTION    "Comment entered by StrataView user to further
      qualify the Circuit Line."
  ::=    { cirLineEntry 6 }

cirLineActive      OBJECT-TYPE
  SYNTAX    Active
  ACCESS    read-only
  STATUS    mandatory
  DESCRIPTION    "Circuit Line Active State."
  ::=    { cirLineEntry 7 }

cirLineStatus      OBJECT-TYPE
  SYNTAX    INTEGER  {
        inactive(1),
        clear(2),
        fail(3),
        down(4)
      }
  ACCESS    read-only
  STATUS    mandatory
  DESCRIPTION    "Circuit Line Status."
  ::=    { cirLineEntry 8 }

-----------------------------------------------------------------------
--  Frame Relay Port Group
-----------------------------------------------------------------------

-----------------------------------------------------------------------
--  Frame Relay Port Table
-----------------------------------------------------------------------
frpTable      OBJECT-TYPE
  SYNTAX    SEQUENCE OF FrpEntry
  ACCESS    not-accessible
  STATUS    obsolete
  DESCRIPTION    "The table of Frame Relay Ports."

  ::=    { frpGroup 1 }

frpEntry      OBJECT-TYPE
  SYNTAX    FrpEntry
  ACCESS    not-accessible
  STATUS    obsolete
  DESCRIPTION    "An entry in the Frame Relay Ports table."
  INDEX    { frpLocalSlot, frpLocalPort }
  ::=    { frpTable 1 }

FrpEntry  ::=  SEQUENCE {
  frpLocalSlot        INTEGER,
  frpLocalPort        INTEGER,
  frpPortSpeed        INTEGER,
  frpComment        DisplayString,
  frpActive        Active,
  frpStatus        INTEGER,
  frpQDepth        INTEGER,
  frpEcnThreshold        INTEGER,
  frpDeThreshold        INTEGER,
  frpPortType        INTEGER,
  frpLocalLine        INTEGER
}

frpLocalSlot      OBJECT-TYPE
  SYNTAX    INTEGER
  ACCESS    read-only
  STATUS    obsolete
  DESCRIPTION    "Local Slot Number."
  ::=    { frpEntry 3 }

frpLocalPort      OBJECT-TYPE
  SYNTAX    INTEGER
  ACCESS    read-only
  STATUS    obsolete
  DESCRIPTION    "Local Port Number.  These are numbered
       starting at 1."
  ::=    { frpEntry 4 }

frpPortSpeed      OBJECT-TYPE
  SYNTAX    INTEGER
  ACCESS    read-only
  STATUS    obsolete
  DESCRIPTION    "Port Speed in bits per second."
  ::=    { frpEntry 5 }

frpComment      OBJECT-TYPE
  SYNTAX    DisplayString (SIZE(0..22))
  ACCESS    read-only
  STATUS    obsolete
  DESCRIPTION    "StrataView User comment used to further
      qualify the Frame Relay Port."
  ::=    { frpEntry 6 }

frpActive      OBJECT-TYPE
  SYNTAX    Active
  ACCESS    read-only
  STATUS    obsolete
  DESCRIPTION    "Frame Relay Port Active State."
  ::=    { frpEntry 7 }

frpStatus      OBJECT-TYPE
  SYNTAX    INTEGER  {
        inactive(1),
        clear(2),

        fail(3),
        down(4)
      }
  ACCESS    read-only
  STATUS    obsolete
  DESCRIPTION    "Frame Relay Port Status."
  ::=    { frpEntry 8 }

frpQDepth      OBJECT-TYPE
  SYNTAX    INTEGER
  ACCESS    read-only
  STATUS    obsolete
  DESCRIPTION    "Frame Relay Port queue depth."
  ::=    { frpEntry 9 }

frpEcnThreshold      OBJECT-TYPE
  SYNTAX    INTEGER
  ACCESS    read-only
  STATUS    obsolete
  DESCRIPTION    "Frame Relay Port ECN queue threshold."
  ::=    { frpEntry 10 }

frpDeThreshold      OBJECT-TYPE
  SYNTAX    INTEGER
  ACCESS    read-only
  STATUS    obsolete
  DESCRIPTION    "Frame Relay Port DE threshold."
  ::=    { frpEntry 11 }

frpPortType      OBJECT-TYPE
  SYNTAX    INTEGER  {
        uni(1),
        nni(2),
        aip(3)
        not-defined(4),
        frsm(5),
        portConcent(6)
      }
  ACCESS    read-only
  STATUS    obsolete
  DESCRIPTION    "Frame relay port type. "
  ::=    { frpEntry 12 }

frpLocalLine      OBJECT-TYPE
  SYNTAX    INTEGER
  ACCESS    read-only
  STATUS    mandatory
  DESCRIPTION    "Local Line Number."
  ::=    { frpEntry 13 }

-----------------------------------------------------------------------
--  Connection Group
-----------------------------------------------------------------------

-----------------------------------------------------------------------
--  Connection Table
-----------------------------------------------------------------------
connTable      OBJECT-TYPE
  SYNTAX    SEQUENCE OF ConnEntry
  ACCESS    not-accessible
  STATUS    obsolete
  DESCRIPTION    "The table of Connections."
  ::=    { connGroup 1 }

connEntry      OBJECT-TYPE

  SYNTAX    ConnEntry
  ACCESS    not-accessible
  STATUS    mandatory
  DESCRIPTION    "An entry in the Connections table."
  INDEX    { connLocalSlot, connLocalChannel, connLocalDLCI }
  ::=    { connTable 1 }

ConnEntry  ::=  SEQUENCE {
  connLocalSlot    INTEGER,
  connLocalChannel    INTEGER,
  connLocalDLCI    INTEGER,
  connRemoteNodeId    INTEGER,
  connRemoteSlot    INTEGER,
  connRemoteChannel    INTEGER,
  connRemoteDLCI    INTEGER,
  connType    INTEGER,
  connRate    INTEGER,
  connLocalMaxPkts    INTEGER,
  connRemoteMaxPkts    INTEGER,
  connMinBandwidth    INTEGER,
  connDAX    INTEGER,
  connTXR    INTEGER,
  connComment    DisplayString,
  connActive    Active,
  connStatus    INTEGER,
  connQir    INTEGER,
  connPir    INTEGER,
  connVcQueDepth    INTEGER,
  connVcQueThreshold    INTEGER,
  connCMax    INTEGER,
  connPerUtil    INTEGER,
  connConnInfoFlag    INTEGER,
  connCir    INTEGER,
  connABitStatus    INTEGER,
  connLocalLine    INTEGER
      }

connLocalSlot      OBJECT-TYPE
  SYNTAX    INTEGER
  ACCESS    read-only
  STATUS    mandatory
  DESCRIPTION    "Local Slot Number."
  ::=    { connEntry 3 }

connLocalChannel      OBJECT-TYPE
  SYNTAX    INTEGER
  ACCESS    read-only
  STATUS    mandatory
  DESCRIPTION    "Local Channel Number.  These are numbered
       starting at 1."
  ::=    { connEntry 4 }

connLocalDLCI      OBJECT-TYPE
  SYNTAX    INTEGER
  ACCESS    read-only
  STATUS    mandatory
  DESCRIPTION    "Local DLCI Number."
  ::=    { connEntry 5 }

connRemoteNodeId      OBJECT-TYPE
  SYNTAX    INTEGER
  ACCESS    read-only
  STATUS    mandatory
  DESCRIPTION    "Remote StrataView Node ID."
  ::=    { connEntry 6 }


connRemoteSlot      OBJECT-TYPE
  SYNTAX    INTEGER
  ACCESS    read-only
  STATUS    mandatory
  DESCRIPTION    "Remote Slot Number."
  ::=    { connEntry 7 }

connRemoteChannel      OBJECT-TYPE
  SYNTAX    INTEGER
  ACCESS    read-only
  STATUS    mandatory
  DESCRIPTION    "Remote Channel Number.  These are
       numbered starting at 1."
  ::=    { connEntry 8 }

connRemoteDLCI      OBJECT-TYPE
  SYNTAX    INTEGER
  ACCESS    read-only
  STATUS    mandatory
  DESCRIPTION    "Remote DLCI Number."
  ::=    { connEntry 9 }

connType      OBJECT-TYPE
  SYNTAX    INTEGER  { voice-dsi-adpcm    (1),
          voice-dsi    (2),
          voice      (3),
          voice-adpcm    (4),
          data      (5),
          frame-relay    (6) }
  ACCESS    read-only
  STATUS    mandatory
  DESCRIPTION    "Connection Type."
  ::=    { connEntry 10 }

connRate      OBJECT-TYPE
  SYNTAX    INTEGER
  ACCESS    read-only
  STATUS    mandatory
  DESCRIPTION    "Combination Field of Rate Info.  The value
       for this variable is generated by ORing
       together the following:
        0x80 -> Fast Eia Enabled
        0x40 -> DFM Enabled

        0x08 -> 7/8 Encoding
        0x10 -> 8/8 Encoding
        0x18 -> 8/8 Inverted Encoding
        0x20 -> 7/8 Inverted Encoding

        0x01 -> Voice
        0x02 -> Non-Time Stamped
                0x03 -> Time Stamped
        0x04 -> bursty data
        0x05 -> multicast
      These form four fields: bit 7, bit 6, 
      bits 3-5, and bits 0-2."
  ::=    { connEntry 11 }

connLocalMaxPkts      OBJECT-TYPE
  SYNTAX    INTEGER
  ACCESS    read-only
  STATUS    mandatory
  DESCRIPTION    "Local maximum number of packets per second
      allocated."

  ::=    { connEntry 12 }

connRemoteMaxPkts      OBJECT-TYPE
  SYNTAX    INTEGER
  ACCESS    read-only
  STATUS    mandatory
  DESCRIPTION    "Remote maximum number of packets per second
      allocated."
  ::=    { connEntry 13 }

connMinBandwidth      OBJECT-TYPE
  SYNTAX    INTEGER
  ACCESS    read-only
  STATUS    mandatory
  DESCRIPTION    "Minimum guaranteed bandwidth in bits per
      second.  Zero if not meaningful."
  ::=    { connEntry 14 }

connDAX      OBJECT-TYPE
  SYNTAX    INTEGER  { non-dax(1), dax(2) }
  ACCESS    read-only
  STATUS    mandatory
  DESCRIPTION    "Flag to identify DAX connection."
  ::=    { connEntry 15 }

connTXR      OBJECT-TYPE
  SYNTAX    INTEGER  { non-txr(1), txr(2) }
  ACCESS    read-only
  STATUS    mandatory
  DESCRIPTION    "Flag to identify voice connection end point
      card is TXR card type."
  ::=    { connEntry 16 }

connComment      OBJECT-TYPE
  SYNTAX    DisplayString (SIZE(0..22))
  ACCESS    read-only
  STATUS    mandatory
  DESCRIPTION    "StrataView user entered comment field used to
      further qualify the connection."
  ::=    { connEntry 17 }

connActive      OBJECT-TYPE
  SYNTAX    Active
  ACCESS    read-only
  STATUS    mandatory
  DESCRIPTION    "Connection Active State."
  ::=    { connEntry 18 }

connStatus      OBJECT-TYPE
  SYNTAX    INTEGER  {
        inactive(1),
        clear(2),
        fail(3),
        down(4)
      }
  ACCESS    read-only
  STATUS    mandatory
  DESCRIPTION    "Connection Status."
  ::=    { connEntry 19 }

connQir      OBJECT-TYPE
  SYNTAX    INTEGER
  ACCESS    read-only
  STATUS    mandatory
  DESCRIPTION    "Connection QIR. (bits per sec)"

  ::=    { connEntry 20 }

connPir      OBJECT-TYPE
  SYNTAX    INTEGER
  ACCESS    read-only
  STATUS    mandatory
  DESCRIPTION    "Connection PIR."
  ::=    { connEntry 21 }

connVcQueDepth      OBJECT-TYPE
  SYNTAX    INTEGER
  ACCESS    read-only
  STATUS    mandatory
  DESCRIPTION    "Connection VcQueDepth."
  ::=    { connEntry 22 }

connVcQueThreshold      OBJECT-TYPE
  SYNTAX    INTEGER
  ACCESS    read-only
  STATUS    mandatory
  DESCRIPTION    "Connection VcQueThreshold."
  ::=    { connEntry 23 }

connCMax      OBJECT-TYPE
  SYNTAX    INTEGER
  ACCESS    read-only
  STATUS    mandatory
  DESCRIPTION    "Connection maximum threshold for FRP credit
      manager."
  ::=    { connEntry 24 }

connPerUtil      OBJECT-TYPE
  SYNTAX    INTEGER
  ACCESS    read-only
  STATUS    mandatory
  DESCRIPTION    "Connection Percent utilization."
  ::=    { connEntry 25 }

connConnInfoFlag      OBJECT-TYPE
  SYNTAX    INTEGER
  ACCESS    read-only
  STATUS    mandatory
  DESCRIPTION    "Connection information flags.  The flags are 
       define as:

      bit 6  snaPriorityHigh - decimal 64
      bit 7  forsightEnabled - decimal 128

      A value of 0 indicates no bits are set."
  ::=    { connEntry 26 }

connCir      OBJECT-TYPE
  SYNTAX    INTEGER
  ACCESS    read-only
  STATUS    mandatory
  DESCRIPTION    "Connection CIR.(bits per sec)"
  ::=    { connEntry 27 }

connABitStatus      OBJECT-TYPE
  SYNTAX    INTEGER
  ACCESS    read-only
  STATUS    mandatory
  DESCRIPTION    "Connection Bit status field.  The fields 
      defined are:
 

      bit 6  remotePacketLine - decimal 64
      bit 7  aBitOk - decimal 128.

      A value of 0 indicates no bits are set."
  ::=    { connEntry 28 }

connLocalLine      OBJECT-TYPE
  SYNTAX    INTEGER
  ACCESS    read-only
  STATUS    mandatory
  DESCRIPTION    "Local Line Number. Valid only for AXIS"
  ::=    { connEntry 29 }

--
-- Real Time Counters Group  
--

--
-- packet Line Real Time Counters table has been deleted and replace by
-- the TrunkLine Real Time Counters table beginning with
-- StrataView Plus release ???

--
--PktLineRTCTable      OBJECT-TYPE
--  SYNTAX    SEQUENCE OF PktLineRTCEntry
--  ACCESS    not-accessible
--  STATUS    mandatory
--  DESCRIPTION    "The table of Packet s Line statistics."
--  ::=    { realTimeCountersGroup 1 }


--
-- circuit Line Real Time Counters table
--
cirLineRTCTable      OBJECT-TYPE
  SYNTAX    SEQUENCE OF CirLineRTCEntry
  ACCESS    not-accessible
  STATUS    mandatory
  DESCRIPTION    "The table of Circuit Line statistics."
  ::=    { realTimeCountersGroup 2 }

cirLineRTCEntry      OBJECT-TYPE
  SYNTAX    CirLineRTCEntry
  ACCESS    not-accessible
  STATUS    mandatory
  DESCRIPTION    "An entry in the Circuit Line 
      statistics table.
      Each row may be sparse."
  INDEX    { cirLineRTCLineNumber }
  ::=    { cirLineRTCTable 1 }

CirLineRTCEntry ::=    SEQUENCE {
  --
  -- All of the Counters in this table can be very time-expensive
  -- to retrieve, taking as much as 10 seconds each.
  -- Manger timeout values should be adjusted accordingly, and
  -- Get-Next walks through this portion of the table should be
  -- avoided.
  --
  cirLineRTCLineNumber      INTEGER,
  cirLineRTCBipolarViolations      Counter,
  cirLineRTCFrameSlips      Counter,
  cirLineRTCOutOfFrames      Counter,
  cirLineRTCLossesOfSignal      Counter,
  cirLineRTCFrameBitErrors      Counter,

  cirLineRTCCrcErrors      Counter,
  cirLineRTCOutOfMultiFrames      Counter,
  cirLineRTCAllOnesInTimeslot16      Counter
}

cirLineRTCLineNumber      OBJECT-TYPE
  SYNTAX    INTEGER
  ACCESS    read-only
  STATUS    mandatory
  DESCRIPTION    "Circuit Line Number."
  ::=    { cirLineRTCEntry 1 }

cirLineRTCBipolarViolations
      OBJECT-TYPE
  SYNTAX    Counter
  ACCESS    read-only
  STATUS    mandatory
  DESCRIPTION    "The number of bipolar violations which have
      occurred on the line.  This statistic is valid
      for T1 circuits only."
  ::=    { cirLineRTCEntry 4 }

cirLineRTCFrameSlips      OBJECT-TYPE
  SYNTAX    Counter
  ACCESS    read-only
  STATUS    mandatory
  DESCRIPTION    "The number of frame slips which have occurred
      on the receive side of the line.  This
      statistic is valid for TXR lines only.  CIP
      and CDP cards do not support this statistic."
  ::=    { cirLineRTCEntry 5 }

cirLineRTCOutOfFrames      OBJECT-TYPE
  SYNTAX    Counter
  ACCESS    read-only
  STATUS    mandatory
  DESCRIPTION    "The number of 0 -> 1 transitions of the out of
      frame conditions as detected by the hardware."
  ::=    { cirLineRTCEntry 6 }

cirLineRTCLossesOfSignal
      OBJECT-TYPE
  SYNTAX    Counter
  ACCESS    read-only
  STATUS    mandatory
  DESCRIPTION    "The number of 0 -> 1 transitions of the loss
       of signal condition as detected by the
       hardware.
       This statistic is valid on CIP and CDP lines
       only.  TXR lines do not support this
       statistic."
  ::=    { cirLineRTCEntry 7 }

cirLineRTCFrameBitErrors
      OBJECT-TYPE
  SYNTAX    Counter
  ACCESS    read-only
  STATUS    mandatory
  DESCRIPTION    "The number of frame alignment signal errors
      which are detected on a line.  This statistic
      is valid only on lines supported by CIP and
      CDP cards.  TXR cards do not support this
      statistic."
  ::=    { cirLineRTCEntry 8 }


cirLineRTCCrcErrors      OBJECT-TYPE
  SYNTAX    Counter
  ACCESS    read-only
  STATUS    mandatory
  DESCRIPTION    "The number of CRC errors detected on
       the line.
      This statistic is valid on lines supported by
      CIP and CDP cards.  TXR cards do no support
      this statistic."
  ::=    { cirLineRTCEntry 9 }

cirLineRTCOutOfMultiFrames
      OBJECT-TYPE
  SYNTAX    Counter
  ACCESS    read-only
  STATUS    mandatory
  DESCRIPTION    "The number of 0 -> 1 transitions into out of
      multi-frame as detected by the hardware.  This
      statistic is valid only on E1 lines.  T1 lines
      do not support this statistic."
  ::=    { cirLineRTCEntry 10 }

cirLineRTCAllOnesInTimeslot16
      OBJECT-TYPE
  SYNTAX    Counter
  ACCESS    read-only
  STATUS    mandatory
  DESCRIPTION    "The number of 0 -> 1 transitions of AIS-16.
      This statistic is valid only for CIP 
      and CDP E1 format lines."
  ::=    { cirLineRTCEntry 11 }

--
-- Frame relay Real Time Counters table
--
frpRTCTable      OBJECT-TYPE
  SYNTAX    SEQUENCE OF FrpRTCEntry
  ACCESS    not-accessible
  STATUS    mandatory
  DESCRIPTION    "The table of frame relay statistics."
  ::=    { realTimeCountersGroup 3 }

frpRTCEntry      OBJECT-TYPE
  SYNTAX    FrpRTCEntry
  ACCESS    not-accessible
  STATUS    mandatory
  DESCRIPTION    "An entry in the frame relay statistics table.
       Each row may be sparse."
  INDEX    { frpRTCSlot, frpRTCPort }
  ::=    { frpRTCTable 1 }

FrpRTCEntry   ::=  SEQUENCE {
  --
  -- All of the Counters in this table can be very time-expensive
  -- to retrieve, taking as much as 10 seconds each.
  -- Manger timeout values should be adjusted accordingly, and
  -- Get-Next walks through this portion of the table should be
  -- avoided.
  --
  frpRTCSlot      INTEGER,
  frpRTCPort      INTEGER,
  frpRTCFramesRcvd      Counter,
  frpRTCFramesXmitted      Counter,
  frpRTCBytesRcvd      Counter,
  frpRTCBytesXmitted      Counter,

  frpRTCFramesXmittedWithFECN      Counter,
  frpRTCFramesXmittedWithBECN      Counter,
  frpRTCFramesRcvdCrcErrors      Counter,
  frpRTCFramesRcvdInvalidFormat      Counter,
  frpRTCFramesRcvdAlignmentErrors      Counter,
  frpRTCFramesRcvdIllegalLen      Counter,
  frpRTCDmaOverruns      Counter,
  frpRTCLmiStatusEnquires      Counter,
  frpRTCLmiStatusXmitRate      Counter,
  frpRTCLmiStatusUpdateRate      Counter,
  frpRTCLmiInvalidStatusEnquires      Counter,
  frpRTCLmiLinkTimeoutErrors      Counter,
  frpRTCLmiKeepaliveSequenceErrors      Counter,
  frpRTCFramesRcvdUndefDlciErrors      Counter,
  frpRTCXmitStatusEnquirey      Counter,
  frpRTCRxStatusCounter      Counter,
  frpRTCAsyncStatusCounter      Counter,
  frpRTCBadSequenceNumberCount      Counter,
  frpRTCTxProtocolTimeOutCount      Counter,
  frpRTCCLLMFramesTx      Counter,
  frpRTCCLLMBytesTx      Counter,
  frpRTCCLLMFramesRx      Counter,
  frpRTCCLLMBytesRx      Counter,
  frpRTCCLLMFailures      Counter,
  frpRTCRxDEFramesDiscarded      Counter,
  frpRTCLine      INTEGER
}

frpRTCSlot      OBJECT-TYPE
  SYNTAX    INTEGER
  ACCESS    read-only
  STATUS    mandatory
  DESCRIPTION    "Local Slot Number."
  ::=    { frpRTCEntry 1 }

frpRTCPort      OBJECT-TYPE
  SYNTAX    INTEGER
  ACCESS    read-only
  STATUS    mandatory
  DESCRIPTION    "Local Port Number.  These are numbered
       starting at 1."
  ::=    { frpRTCEntry 2 }

frpRTCFramesRcvd      OBJECT-TYPE
  SYNTAX    Counter
  ACCESS    read-only
  STATUS    mandatory
  DESCRIPTION    "The number of frames received by the FRP
       port."
  ::=    { frpRTCEntry 4 }

frpRTCFramesXmitted      OBJECT-TYPE
  SYNTAX    Counter
  ACCESS    read-only
  STATUS    mandatory
  DESCRIPTION    "The number of frames transmitted out the FRP
      port."
  ::=    { frpRTCEntry 5 }

frpRTCBytesRcvd      OBJECT-TYPE
  SYNTAX    Counter
  ACCESS    read-only
  STATUS    mandatory
  DESCRIPTION    "The number of frame bytes received from the
       FRP port."

  ::=    { frpRTCEntry 6 }

frpRTCBytesXmitted      OBJECT-TYPE
  SYNTAX    Counter
  ACCESS    read-only
  STATUS    mandatory
  DESCRIPTION    "The number of frame bytes transmitted out the
       FRP port."
  ::=    { frpRTCEntry 7 }

frpRTCFramesXmittedWithFECN      OBJECT-TYPE
  SYNTAX    Counter
  ACCESS    read-only
  STATUS    mandatory
  DESCRIPTION    "The number of frames transmitted out the FRP
      port with the FECN bit set."
  ::=    { frpRTCEntry 8 }

frpRTCFramesXmittedWithBECN      OBJECT-TYPE
  SYNTAX    Counter
  ACCESS    read-only
  STATUS    mandatory
  DESCRIPTION    "The number of frames transmitted out the FRP
      port with the BECN bit set."
  ::=    { frpRTCEntry 9 }

frpRTCFramesRcvdCrcErrors      OBJECT-TYPE
  SYNTAX    Counter
  ACCESS    read-only
  STATUS    mandatory
  DESCRIPTION    "The number of CRC errors on received frames
      for the FRP port."
  ::=    { frpRTCEntry 10 }

frpRTCFramesRcvdInvalidFormat      OBJECT-TYPE
  SYNTAX    Counter
  ACCESS    read-only
  STATUS    mandatory
  DESCRIPTION    "The number of frames received by the FRP port
      which contain incorrect EA bit settings (1 in
      the first byte and/or 0 in the second byte)."
  ::=    { frpRTCEntry 11 }

frpRTCFramesRcvdAlignmentErrors      OBJECT-TYPE
  SYNTAX    Counter
  ACCESS    read-only
  STATUS    mandatory
  DESCRIPTION    "The number of bit alignment errors 
      on received frames for the FRP port."
  ::=    { frpRTCEntry 12 }

frpRTCFramesRcvdIllegalLen      OBJECT-TYPE
  SYNTAX    Counter
  ACCESS    read-only
  STATUS    mandatory
  DESCRIPTION    "The number of frames received by the FRP 
      port which exceed the maximum 
      allowed frame length."
  ::=    { frpRTCEntry 13 }

frpRTCDmaOverruns      OBJECT-TYPE
  SYNTAX    Counter
  ACCESS    read-only
  STATUS    mandatory
  DESCRIPTION    "The number of DMA overruns on the FRP port."

  ::=    { frpRTCEntry 14 }

frpRTCLmiStatusEnquires      OBJECT-TYPE
  SYNTAX    Counter
  ACCESS    read-only
  STATUS    mandatory
  DESCRIPTION    "The number of LMI status enquires received
      from the user device by the FRP port."
  ::=    { frpRTCEntry 15 }

frpRTCLmiStatusXmitRate      OBJECT-TYPE
  SYNTAX    Counter
  ACCESS    read-only
  STATUS    mandatory
  DESCRIPTION    "The number of LMI status messages transmitted
      to the user device from the FRP port per ??."
  ::=    { frpRTCEntry 16 }

frpRTCLmiStatusUpdateRate      OBJECT-TYPE
  SYNTAX    Counter
  ACCESS    read-only
  STATUS    mandatory
  DESCRIPTION    "The number of LMI update messages transmitted
      to the user device from the FRP port per ??."
  ::=    { frpRTCEntry 17 }

frpRTCLmiInvalidStatusEnquires      OBJECT-TYPE
  SYNTAX    Counter
  ACCESS    read-only
  STATUS    mandatory
  DESCRIPTION    "The number of invalid LMI status enquires
      received from the user device by the
      FRP port."
  ::=    { frpRTCEntry 18 }

frpRTCLmiLinkTimeoutErrors      OBJECT-TYPE
  SYNTAX    Counter
  ACCESS    read-only
  STATUS    mandatory
  DESCRIPTION    "The number of LMI link timeout errors."
  ::=    { frpRTCEntry 19 }

frpRTCLmiKeepaliveSequenceErrors      OBJECT-TYPE
  SYNTAX    Counter
  ACCESS    read-only
  STATUS    mandatory
  DESCRIPTION    "The number of LMI keepalive sequence number
      errors."
  ::=    { frpRTCEntry 20 }

frpRTCFramesRcvdUndefDlciErrors      OBJECT-TYPE
  SYNTAX    Counter
  ACCESS    read-only
  STATUS    mandatory
  DESCRIPTION    "The number of frames received by the FRP port
      which contain undefined DLCIs."
  ::=    { frpRTCEntry 21 }

frpRTCXmitStatusEnquirey      OBJECT-TYPE
  SYNTAX    Counter
  ACCESS    read-only
  STATUS    mandatory
  DESCRIPTION    "Transmit Status Enquirey."
  ::=    { frpRTCEntry 22 }


frpRTCRxStatusCounter      OBJECT-TYPE
  SYNTAX    Counter
  ACCESS    read-only
  STATUS    mandatory
  DESCRIPTION    "Received Status counter."
  ::=    { frpRTCEntry 23 }

 frpRTCAsyncStatusCounter      OBJECT-TYPE
  SYNTAX    Counter
  ACCESS    read-only
  STATUS    mandatory
  DESCRIPTION    "Asynchronous Status Counter."
  ::=    { frpRTCEntry 24 }

 frpRTCBadSequenceNumberCount      OBJECT-TYPE
  SYNTAX    Counter
  ACCESS    read-only
  STATUS    mandatory
  DESCRIPTION    "Invalid Sequence number count."
  ::=    { frpRTCEntry 25 }

 frpRTCTxProtocolTimeOutCount      OBJECT-TYPE
  SYNTAX    Counter
  ACCESS    read-only
  STATUS    mandatory
  DESCRIPTION    "Transmit Protocol timeout count."
  ::=    { frpRTCEntry 26 }

 frpRTCCLLMFramesTx      OBJECT-TYPE
  SYNTAX    Counter
  ACCESS    read-only
  STATUS    mandatory
  DESCRIPTION    "CLLM message frames transmitted."
  ::=    { frpRTCEntry 27 }

 frpRTCCLLMBytesTx      OBJECT-TYPE
  SYNTAX    Counter
  ACCESS    read-only
  STATUS    mandatory
  DESCRIPTION    "CLLM message bytes transmitted."
  ::=    { frpRTCEntry 28 }

 frpRTCCLLMFramesRx      OBJECT-TYPE
  SYNTAX    Counter
  ACCESS    read-only
  STATUS    mandatory
  DESCRIPTION    "CLLM Frames received."
  ::=    { frpRTCEntry 29 }

 frpRTCCLLMBytes  x    OBJECT-TYPE
  SYNTAX    Counter
  ACCESS    read-only
  STATUS    mandatory
  DESCRIPTION    "CLLM bytes received."
  ::=    { frpRTCEntry 30 }

 frpRTCCLLMFailures      OBJECT-TYPE
  SYNTAX    Counter
  ACCESS    read-only
  STATUS    mandatory
  DESCRIPTION    "CLLM failures."
  ::=    { frpRTCEntry 31 }

frpRTCRxDEFramesDiscarded      OBJECT-TYPE
  SYNTAX    Counter

  ACCESS    read-only
  STATUS    mandatory
  DESCRIPTION    "The number of frames with the DE bit set
        which have been dropped by the frame relay
       port.  IPX software versions earlier than
       IPX 6.1 will report a count of zero."
  ::=    { frpRTCEntry 32}

frpRTCLine      OBJECT-TYPE
  SYNTAX    INTEGER
  ACCESS    read-only
  STATUS    mandatory
  DESCRIPTION    "Local Slot Number."
  ::=    { frpRTCEntry 33 }

--
-- Connection Real Time Counters Table
--

connRTCTable      OBJECT-TYPE
  SYNTAX    SEQUENCE OF ConnRTCEntry
  ACCESS    not-accessible
  STATUS    mandatory
  DESCRIPTION    "The table of Connection statistics."
  ::=    { realTimeCountersGroup 4 }

connRTCEntry      OBJECT-TYPE
  SYNTAX    ConnRTCEntry
  ACCESS    not-accessible
  STATUS    mandatory
  DESCRIPTION    "An entry in the Connection statistics table."
  INDEX    { connRTCSlot, connRTCChannel, connRTCDLCI }
  ::=    { connRTCTable 1 }


ConnRTCEntry  ::=  SEQUENCE {
  --
  -- All of the Counters in this table can be very time-expensive
  -- to retrieve, taking as much as 10 seconds each.
  -- Manger timeout values should be adjusted accordingly, and
  -- Get-Next walks through this portion of the table should be
  -- avoided.
  --
  connRTCSlot      INTEGER,
  connRTCChannel      INTEGER,
  connRTCDLCI      INTEGER,
  connRTCRcvdFrames      Counter,
  connRTCRcvdFramesDiscarded      Counter,
  connRTCXmitFrames      Counter,
  connRTCXmitFramesDiscarded      Counter,
  connRTCRcvdPkts      Counter,
  connRTCRcvdPktsDiscarded      Counter,
  connRTCXmitPkts      Counter,
  connRTCXmitPktsProjected      Counter,
  connRTCXmitPktsSupervisory      Counter,
  connRTCRcvdBytes      Counter,
  connRTCRcvdBytesDiscarded      Counter,
  connRTCXmitBytes      Counter,
  connRTCXmitBytesDiscarded      Counter,
  connRTCSecondsV25ModemOn      Counter,
  connRTCSecondsDsiEnabled      Counter,
  connRTCSecondsOffHook      Counter,
  connRTCSecondsInService      Counter,
  connRTCXmitFramesWithFECN      Counter,
  connRTCXmitFramesWithBECN      Counter,

  connRTCRxSupervisoryPkts      Counter,
  connRTCCongestedMinuites      Counter,
  connRTCFramesRxWithDE      Counter,
  connRTCFramesTxWithDE      Counter,
  connRTCFramesDiscardedWithDE      Counter,
  connRTCBytesRxWithDE      Counter,
  connRTCFramesRxExcessCir      Counter,
  connRTCBytesRxExcessCir      Counter,
  connRTCLine      INTEGER
}
connRTCSlot      OBJECT-TYPE
  SYNTAX    INTEGER
  ACCESS    read-only
  STATUS    mandatory
  DESCRIPTION    "Local Slot Number."
  ::=    { connRTCEntry 1 }

connRTCChannel      OBJECT-TYPE
  SYNTAX    INTEGER
  ACCESS    read-only
  STATUS    mandatory
  DESCRIPTION    "Local Channel Number.  These are numbered
       starting at 1."
  ::=    { connRTCEntry 2 }

connRTCDLCI      OBJECT-TYPE
  SYNTAX    INTEGER
  ACCESS    read-only
  STATUS    mandatory
  DESCRIPTION    "Local DLCI Number."
  ::=    { connRTCEntry 3 }

connRTCRcvdFrames      OBJECT-TYPE
  SYNTAX    Counter
  ACCESS    read-only
  STATUS    mandatory
  DESCRIPTION    "The number of frames received from the FRP
        port associated with the connection.  This 
       statistic is valid for Frame Relay
       Connections only."
  ::=    { connRTCEntry 4 }

connRTCRcvdFramesDiscarded      OBJECT-TYPE
  SYNTAX    Counter
  ACCESS    read-only
  STATUS    mandatory
  DESCRIPTION    "The number of frames received from the FRP
      port which are associated with the connection,
      but were discarded before being transmitted
      onto the Muxbus due to the age of the frame
      in the IPX system or the lack of buffer space.
      This statistic is valid for Frame Relay
      Connections only."
  ::=    { connRTCEntry 5 }

connRTCXmitFrames      OBJECT-TYPE
  SYNTAX    Counter
  ACCESS    read-only
  STATUS    mandatory
  DESCRIPTION    "The number of frames transmitted out the FRP
      port which were received from the other
      endpoint of the connection.  This statistic is
      valid for Frame Relay connections only."
  ::=    { connRTCEntry 6 }


connRTCXmitFramesDiscarded      OBJECT-TYPE
  SYNTAX    Counter
  ACCESS    read-only
  STATUS    mandatory
  DESCRIPTION    "The number of frames to be transmitted out
       the FRP port which were received from the 
       other endpoint of the connection, but were
       discarded due to the age of the frame in the
       IPX system, a CRC error, or lack of buffer
       space.  This statistic is valid for Frame
       Relay Connections only."
  ::=    { connRTCEntry 7 }

connRTCRcvdPkts      OBJECT-TYPE
  SYNTAX    Counter
  ACCESS    read-only
  STATUS    mandatory
  DESCRIPTION    "The number of packets received from the
       Muxbus by the FRP port associated with the
       connection endpoint.  This statistic is
       valid for Frame Relay Connections only."
  ::=    { connRTCEntry 8 }

connRTCRcvdPktsDiscarded      OBJECT-TYPE
  SYNTAX    Counter
  ACCESS    read-only
  STATUS    mandatory
  DESCRIPTION    "The number of packets received from the
       Muxbus at the FRP port associated with the
       connection endpoint, but were discarded
       before being assembled into frames and
       transmitted on the FRP port.  This statistic
       is valid for Frame Relay Connections only."
  ::=    { connRTCEntry 9 }

connRTCXmitPkts      OBJECT-TYPE
  SYNTAX    Counter
  ACCESS    read-only
  STATUS    mandatory
  DESCRIPTION    "The number of packets transmitted from one
      connection endpoint onto the Muxbus towards
      the other connection endpoint.  This statistic
      is valid for all types of inter-node
      connections, and for CDP Data, FRP, LDP and
      SDP terminated DAX connections."
  ::=    { connRTCEntry 10 }

connRTCXmitPktsProjected      OBJECT-TYPE
  SYNTAX    Counter
  ACCESS    read-only
  STATUS    mandatory
  DESCRIPTION    "The estimated number of packets which would
      be used if DSI or DFM were enabled for the
      connection.  This statistic is valid for
      inter-node voice connections and with all
      types of data connections.  It is not
      valid for DAX voice connections or Frame
      Relay connections."
  ::=    { connRTCEntry 11 }

connRTCXmitPktsSupervisory      OBJECT-TYPE
  SYNTAX    Counter
  ACCESS    read-only
  STATUS    mandatory
  DESCRIPTION    "The number of supervisory packets transmitted

      from one connection endpoint to another.
      Supervisory packets reflect signaling bit
      transitions for voice connections, and EIA
      lead transitions for data channels.  This
      statistic is valid on all inter-node 'a',
      'c', and 'v' voice connections, all inter-
      node data connections, all 'd' type voice
      connection endpoints which are supported by 
      CIP or CDP cards, and all DAX data conn-
      sections.  This statistic is not valid for
       Frame Relay connections."
  ::=    { connRTCEntry 12 }

connRTCRcvdBytes      OBJECT-TYPE
  SYNTAX    Counter
  ACCESS    read-only
  STATUS    mandatory
  DESCRIPTION    "The number of frame bytes received from the
       FRP port associated with the connection
       endpoint. This statistic is valid for Frame
       Relay connections only."
  ::=    { connRTCEntry 13 }

connRTCRcvdBytesDiscarded      OBJECT-TYPE
  SYNTAX    Counter
  ACCESS    read-only
  STATUS    mandatory
  DESCRIPTION    "The number of frame bytes received from the
      FRP port associated with the connection
      endpoint, but were discarded due to the age of
      the frame in the IPX system or the lack of
      buffer space before being transmitted onto the
      Muxbus.  This statistic is valid for Frame
      Relay connections only."
  ::=    { connRTCEntry 14 }

connRTCXmitBytes      OBJECT-TYPE
  SYNTAX    Counter
  ACCESS    read-only
  STATUS    mandatory
  DESCRIPTION    "The number of frame bytes to be received from
      the Muxbus from the remote end of the
      connection, which were actually transmitted
      out the FRP port as frames.  This statistic is
      valid for Frame Relay connections only."
  ::=    { connRTCEntry 15 }

connRTCXmitBytesDiscarded      OBJECT-TYPE
  SYNTAX    Counter
  ACCESS    read-only
  STATUS    mandatory
  DESCRIPTION    "The number of frame bytes to be received from
      the Muxbus from the remote end of the
      connection, but were discarded due to the age
      of the frame in the IPX system, a CRC error,
      or lack of buffer space.  This statistic is 
      valid for Frame Relay connections only."
  ::=    { connRTCEntry 16 }

connRTCSecondsV25ModemOn      OBJECT-TYPE
  SYNTAX    Counter
  ACCESS    read-only
  STATUS    mandatory
  DESCRIPTION    "The number of seconds the V.25 modem has been
      detected and a connection upgraded from ADPCM

      to PCM.  The status of the V.25 modem detect 
      is checked every 3 seconds, so the granularity
      of the data which makes up this statistic is 3
      seconds.  This statistic is valid for inter-
      node type 'a', 'c' and 'v' voice connections
      only."
  ::=    { connRTCEntry 17 }

connRTCSecondsDsiEnabled      OBJECT-TYPE
  SYNTAX    Counter
  ACCESS    read-only
  STATUS    mandatory
  DESCRIPTION    "The number of seconds that a connection has
      been performing Digital Speech Interpolation
      (DSI).  The status of DSI is checked every 3
      seconds, so the granularity of the data which
      makes up this statistic is 3 seconds.  This
      statistic is valid for inter-node type 'c' and
      'v' voice connections only."
  ::=    { connRTCEntry 18 }

connRTCSecondsOffHook      OBJECT-TYPE
  SYNTAX    Counter
  ACCESS    read-only
  STATUS    mandatory
  DESCRIPTION    "The number of seconds that a voice connection
      has been off-hook.  The on-hook state is
      determined by the signaling bits, as defined 
      by the 'cnfchtp' command.  A connection which 
      is not on-hook is treated as off-hook for this
      statistic.  The status of the off-hook
      condition is checked every 3 seconds,
      so the granularity of the data which makes up
      this statistic is 3 seconds.  This statistic 
      is valid for all 'a', 'c' and 'v' voice
      connections, and for 'd' type voice connection
      endpoints supported by CIP or CDP cards."
  ::=    { connRTCEntry 19 }

connRTCSecondsInService      OBJECT-TYPE
  SYNTAX    Counter
  ACCESS    read-only
  STATUS    mandatory
  DESCRIPTION    "The number of seconds that a connection has
      been in service.  A connection is considered to
      be in service if its end points are not in
      alarm, that cards required to support the
      connection are present, and the connection is
      routed."
  ::=    { connRTCEntry 20 }

connRTCXmitFramesWithFECN      OBJECT-TYPE
  SYNTAX    Counter
  ACCESS    read-only
  STATUS    mandatory
  DESCRIPTION    "The number of frames transmitted out the FRP
      port with the FECN bit set.  This statistic is
      valid for Frame Relay connections only."
  ::=    { connRTCEntry 21 }

connRTCXmitFramesWithBECN      OBJECT-TYPE
  SYNTAX    Counter
  ACCESS    read-only
  STATUS    mandatory
  DESCRIPTION    "The number of frames transmitted out the FRP

      port with the BECN bit set.  This statistic
      is valid for Frame Relay connections only."
  ::=    { connRTCEntry 22 }

connRTCRxSupervisoryPkts      OBJECT-TYPE
  SYNTAX    Counter
  ACCESS    read-only
  STATUS    mandatory
  DESCRIPTION    "The number of supervisory packets
       received."
  ::=    { connRTCEntry 23 }

connRTCCongestedMinuites      OBJECT-TYPE
  SYNTAX    Counter
  ACCESS    read-only
  STATUS    mandatory
  DESCRIPTION    "The number of minutes in which 50%or more 
       frames are tagged FECN by the FRP."
  ::=    { connRTCEntry 24 }

connRTCFramesRxWithDE      OBJECT-TYPE
  SYNTAX    Counter
  ACCESS    read-only
  STATUS    mandatory
  DESCRIPTION    "The number of frames received from the FRP 
      with the DE bit set."
  ::=    { connRTCEntry 25 }

connRTCFramesTxWithDE      OBJECT-TYPE
  SYNTAX    Counter
  ACCESS    read-only
  STATUS    mandatory
  DESCRIPTION    "The number of frames transmitted from the FRP 
      with the DE bit set. "
  ::=    { connRTCEntry 26 }

connRTCFramesDiscardedWithDE      OBJECT-TYPE
  SYNTAX    Counter
  ACCESS    read-only
  STATUS    mandatory
  DESCRIPTION    "The number of frames received from the local
      frame relay port with their DE bit set which 
      are discarded before being transmitted onto
      the Muxbus." 
  ::=    { connRTCEntry 27 }

connRTCBytesRxWithDE      OBJECT-TYPE
  SYNTAX    Counter
  ACCESS    read-only
  STATUS    mandatory
  DESCRIPTION    "The number of bytes received from the FRP 
      for frames with the DE bit set."
  ::=    { connRTCEntry 28 }

connRTCFramesRxExcessCir      OBJECT-TYPE
  SYNTAX    Counter
  ACCESS    read-only
  STATUS    mandatory
  DESCRIPTION    "The number of frames received in excess of
       CIR."
  ::=    { connRTCEntry 29 }

connRTCBytesRxExcessCir      OBJECT-TYPE
  SYNTAX    Counter
  ACCESS    read-only

  STATUS    mandatory
  DESCRIPTION    "The number of bytes received in excess of
       CIR."
  ::=    { connRTCEntry 30 }

connRTCFramesTxExcessCir      OBJECT-TYPE
  SYNTAX    Counter
  ACCESS    read-only
  STATUS    mandatory
  DESCRIPTION    "The number of frames transmitted in excess
       of CIR."
  ::=    { connRTCEntry 31 }

connRTCBytesTxExcessCir      OBJECT-TYPE
  SYNTAX    Counter
  ACCESS    read-only
  STATUS    mandatory
  DESCRIPTION    "The number of bytes transmitted in excess of
       CIR."
  ::=    { connRTCEntry 32 }

connRTCLine      OBJECT-TYPE
  SYNTAX    INTEGER
  ACCESS    read-only
  STATUS    mandatory
  DESCRIPTION    "Line Number, for IPX it is always 0."
  ::=    { connRTCEntry 33 }

--
-- Trunk Real Time Counter Table
--  valid only for SV Plus release ????

trunkRTCTable      OBJECT-TYPE
  SYNTAX    SEQUENCE OF TrunkRTCEntry
  ACCESS    not-accessible
  STATUS    mandatory
  DESCRIPTION    "The table of Trunk Line statistics."
  ::=    { realTimeCountersGroup 5 }

trunkRTCEntry      OBJECT-TYPE
  SYNTAX    TrunkRTCEntry
  ACCESS    not-accessible
  STATUS    mandatory
  DESCRIPTION    "An entry in the Trunk Line statistics table.
      Each row may be sparse."
  INDEX    { trunkRTCLocalSlot, trunkRTCLocalPort }
  ::=    { trunkRTCTable 1 }

TrunkRTCEntry ::=  SEQUENCE {
  --
  -- All of the Counters in this table can be very time-expensive
  -- to retrieve, taking as much as 10 seconds each.
  -- Manger timeout values should be adjusted accordingly, and
  -- Get-Next walks through this portion of the table should be
  -- avoided.
  --
  trunkRTCLocalSlot      INTEGER,
  trunkRTCLocalPort      INTEGER,
  trunkRTCBipolarViolations      Counter,
  trunkRTCFrameSlips      Counter,
  trunkRTCOutOfFrames      Counter,
  trunkRTCLossOfSignal      Counter,
  trunkRTCFrameBitErrors      Counter,
  trunkRTCCrcErrors      Counter,
  trunkRTCPktOutOfFrames      Counter,

  trunkRTCPktCrcErrors      Counter,
  trunkRTCBadClockErrors      Counter,
  trunkRTCVoicePktsDropped      Counter,
  trunkRTCTimeStampedPktsDropped      Counter,
  trunkRTCNonTimeStampedPktsDropped      Counter,
  trunkRTCHighPriorityPktsDropped      Counter,
  trunkRTCBurstyDataPktsDropped      Counter,
  trunkRTCMulticastPktsDropped      Counter,
  trunkRTCVoicePktsXmitted      Counter,
  trunkRTCTimeStampedPktsXmitted      Counter,
  trunkRTCNonTimeStampedPktsXmitted      Counter,
  trunkRTCHighPriorityPktsXmitted      Counter,
  trunkRTCBurstyDataPktsXmitted      Counter,
  trunkRTCMulticastPktsXmitted      Counter,
  trunkRTCPktsXmitted      Counter,
  trunkRTCTxBurstyDataAClpPktsDropped      Counter,
  trunkRTCTxBurstyDataBClpPktsDropped      Counter,
  trunkRTCBurstyDataAEfcnPktsTx2Line      Counter,
  trunkRTCBurstyDataBEfcnPktsTx2Line      Counter,
  trunkRTCBurstyDataAClpPktsTx2Line      Counter,
  trunkRTCBurstyDataBClpPktsTx2Line      Counter,
  trunkRTCAtmCellHeaderHecErrors      Counter,
  trunkRTCTxVoiceCellsDropped      Counter,
  trunkRTCTxTimeStampCellsDropped      Counter,
  trunkRTCTxNonTStampCellsDropped      Counter,
  trunkRTCTxHighPriorityCellsDropped      Counter,
  trunkRTCTxBurstyDataACellsDropped      Counter,
  trunkRTCTxBurstyDataBCellsDropped      Counter,
  trunkRTCVoiceCellsTx2Line      Counter,
  trunkRTCTimeStampCellsTx2Line      Counter,
  trunkRTCNonTimeStampCellsTx2Line      Counter,
  trunkRTCHighPriorityCellsTx2Line      Counter,
  trunkRTCBurstyDataACellsTx2Line      Counter,
  trunkRTCBurstyDataBCellsTx2Line      Counter,
  trunkRTCTotalCellsTx2Line      Counter,
  trunkRTCTxBurstyDataAClpCellsDropped      Counter,
  trunkRTCTxBurstyDataBClpCellsDropped      Counter,
  trunkRTCBurstyDataAEfcnCellsTx2Line      Counter,
  trunkRTCBurstyDataBEfcnCellsTx2Line      Counter,
  trunkRTCPlcpOutOfFrames      Counter
}

trunkRTCLocalSlot      OBJECT-TYPE
  SYNTAX    INTEGER
  ACCESS    read-only
  STATUS    mandatory
  DESCRIPTION    "Local Slot Number.  These are numbered
      starting at 1"
  ::=    { trunkRTCEntry 1 }

trunkRTCLocalPort      OBJECT-TYPE
  SYNTAX    INTEGER
  ACCESS    read-only
  STATUS    mandatory
  DESCRIPTION    "Local Port Number.  These are numbered
       starting at 1."
  ::=    { trunkRTCEntry 2 }

trunkRTCBipolarViolations
      OBJECT-TYPE
  SYNTAX    Counter
  ACCESS    read-only
  STATUS    mandatory
  DESCRIPTION    "The signal level for a '1' bit should
      alternate between a positive and a negative

      signal.  If two positive or two negative
      signals are received in a row, a bipolar
      violation has occurred."
  ::=    { trunkRTCEntry 4 }

trunkRTCFrameSlips  OBJECT-TYPE
  SYNTAX    Counter
  ACCESS    read-only
  STATUS    mandatory
  DESCRIPTION    "The number of frame slips which have occurred
       on the receive side of the line.  This
       statistic is valid for TXR lines only.  NTC 
       cards do not support this statistic."
  ::=    { trunkRTCEntry 5 }

trunkRTCOutOfFrames      OBJECT-TYPE
  SYNTAX    Counter
  ACCESS    read-only
  STATUS    mandatory
  DESCRIPTION    "The number of 0 -> 1 transitions of the out
       of frame condition as detected by the 
       hardware. This statistic is valid for T1 and
       E1 lines only."
  ::=    { trunkRTCEntry 6 }

trunkRTCLossOfSignal      OBJECT-TYPE
  SYNTAX    Counter
  ACCESS    read-only
  STATUS    mandatory
  DESCRIPTION    "The number of 0 -> 1 transitions of the loss
      of signal condition as detected by the
      hardware.  This statistic is valid for NTC
      lines only."
  ::=    { trunkRTCEntry 7 }

trunkRTCFrameBitErrors      OBJECT-TYPE
  SYNTAX    Counter
  ACCESS    read-only
  STATUS    mandatory
  DESCRIPTION    "The number of frame alignment signal errors
      which have been detected on this line.  This
      statistic is valid only on lines supported by
      NTC cards.  TXR and Sub-rate lines do not
      support this statistic.  This statistic is
      also not supported by NTC-T1 in ESF framing
      mode."
  ::=    { trunkRTCEntry 8 }

trunkRTCCrcErrors      OBJECT-TYPE
  SYNTAX    Counter
  ACCESS    read-only
  STATUS    mandatory
  DESCRIPTION    "The number of CRC errors detected on the
       line. This statistic is valid only on lines
       supported by NTC cards.  TXR cards and Sub-
       rate lines do not support this statistic.
       This statistic is also not supported by NTC-
       T1 in D4 framing mode."
  ::=    { trunkRTCEntry 9 }

trunkRTCPktOutOfFrames      OBJECT-TYPE
  SYNTAX    Counter
  ACCESS    read-only
  STATUS    mandatory
  DESCRIPTION    "The number of packets out of frames on this

      line.  This statistic is only valid on lines
      supported by NTC cards.  TXR cards do not
      support this statistic."
  ::=    { trunkRTCEntry 10 }

trunkRTCPktCrcErrors      OBJECT-TYPE
  SYNTAX    Counter
  ACCESS    read-only
  STATUS    mandatory
  DESCRIPTION    "The number of packets received with detected
       CRC errors in the packet headers."
  ::=    { trunkRTCEntry 11 }

trunkRTCBadClockErrors
      OBJECT-TYPE
  SYNTAX    Counter
  ACCESS    read-only
  STATUS    mandatory
  DESCRIPTION    "The number of 0 -> 1 transitions of the loss
       of clock condition as detected by the
       hardware. This statistic is valid on NTC Sub-
       rate lines only.  T1 and E1 lines do not
       support this statistic."
  ::=    { trunkRTCEntry 12 }

trunkRTCVoicePktsDropped      OBJECT-TYPE
  SYNTAX    Counter
  ACCESS    read-only
  STATUS    mandatory
  DESCRIPTION    "The number of voice packets dropped on a
       line."
  ::=    { trunkRTCEntry 13 }

trunkRTCTimeStampedPktsDropped      OBJECT-TYPE
  SYNTAX    Counter
  ACCESS    read-only
  STATUS    mandatory
  DESCRIPTION    "The number of time stamped data packets
       dropped on the line."
  ::=    { trunkRTCEntry 14 }

trunkRTCNonTimeStampedPktsDropped      OBJECT-TYPE
  SYNTAX    Counter
  ACCESS    read-only
  STATUS    mandatory
  DESCRIPTION    "The number of non-time stamped data packets
       dropped on the line."
  ::=    { trunkRTCEntry 15 }

trunkRTCHighPriorityPktsDropped      OBJECT-TYPE
  SYNTAX    Counter
  ACCESS    read-only
  STATUS    mandatory
  DESCRIPTION    "The number of high priority (PCC) packets
       dropped on the line."
  ::=    { trunkRTCEntry 16 }

trunkRTCBurstyDataPktsDropped      OBJECT-TYPE
  SYNTAX    Counter
  ACCESS    read-only
  STATUS    mandatory
  DESCRIPTION    "The number of bursty data packets dropped on
      the line."
  ::=    { trunkRTCEntry 17 }


trunkRTCMulticastPktsDropped      OBJECT-TYPE
  SYNTAX    Counter
  ACCESS    read-only
  STATUS    mandatory
  DESCRIPTION    "The number of Multicast packets dropped on
       the line."
  ::=    { trunkRTCEntry 18 }

trunkRTCVoicePktsXmitted      OBJECT-TYPE
  SYNTAX    Counter
  ACCESS    read-only
  STATUS    mandatory
  DESCRIPTION    "The number of voice packets transmitted onto
      the line."
  ::=    { trunkRTCEntry 19 }

trunkRTCTimeStampedPktsXmitted      OBJECT-TYPE
  SYNTAX    Counter
  ACCESS    read-only
  STATUS    mandatory
  DESCRIPTION    "The number of time stamped packets 
      transmitted onto the line."
  ::=    { trunkRTCEntry 20 }

trunkRTCNonTimeStampedPktsXmitted      OBJECT-TYPE
  SYNTAX    Counter
  ACCESS    read-only
  STATUS    mandatory
  DESCRIPTION    "The number of non-time stamped packets
      transmitted onto the line."
  ::=    { trunkRTCEntry 21 }

trunkRTCHighPriorityPktsXmitted      OBJECT-TYPE
  SYNTAX    Counter
  ACCESS    read-only
  STATUS    mandatory
  DESCRIPTION    "The number of high priority packets
       transmitted onto the line."
  ::=    { trunkRTCEntry 22 }

trunkRTCBurstyDataPktsXmitted      OBJECT-TYPE
  SYNTAX    Counter
  ACCESS    read-only
  STATUS    mandatory
  DESCRIPTION    "The number of bursty data packets transmitted
       onto the line."
  ::=    { trunkRTCEntry 23 }

trunkRTCMulticastPktsXmitted      OBJECT-TYPE
  SYNTAX    Counter
  ACCESS    read-only
  STATUS    mandatory
  DESCRIPTION    "The number of Multicast packets transmitted
       onto the line."
  ::=    { trunkRTCEntry 24 }

trunkRTCPktsXmitted  OBJECT-TYPE
  SYNTAX    Counter
  ACCESS    read-only
  STATUS    mandatory
  DESCRIPTION    "The total number of packets transmitted onto
       the line."
  ::=    { trunkRTCEntry 25 }

trunkRTCTxBurstyDataAClpPktsDropped      OBJECT-TYPE

  SYNTAX    Counter
  ACCESS    read-only
  STATUS    mandatory
  DESCRIPTION    "The number of packets with the CLP bit set
       that are dropped from the bursty data A
       queue."
  ::=    { trunkRTCEntry 26 }

trunkRTCTxBurstyDataBClpPktsDropped      OBJECT-TYPE
  SYNTAX    Counter
  ACCESS    read-only
  STATUS    mandatory
  DESCRIPTION    "The number of packets with the CLP bit set
       that are dropped from the bursty data B
       queue."
  ::=    { trunkRTCEntry 27 }

trunkRTCBurstyDataAEfcnPktsTx2Line      OBJECT-TYPE
  SYNTAX    Counter
  ACCESS    read-only
  STATUS    mandatory
  DESCRIPTION    "The number of packets with the EFCN bit set
       which have been transmitted onto the line
       from the bursty data A queue."
  ::=    { trunkRTCEntry 28 }

trunkRTCBurstyDataBEfcnPktsTx2Line      OBJECT-TYPE
  SYNTAX    Counter
  ACCESS    read-only
  STATUS    mandatory
  DESCRIPTION    "The number of packets with the EFCN bit set
       which have been transmitted onto the line
       from the bursty data B queue."
  ::=    { trunkRTCEntry 29 }

trunkRTCBurstyDataAClpPktsTx2Line      OBJECT-TYPE
  SYNTAX    Counter
  ACCESS    read-only
  STATUS    mandatory
  DESCRIPTION    "The number of packets with the CLP bit set
       which have been transmitted onto the line
       from the bursty data A queue."
  ::=    { trunkRTCEntry 30 }

trunkRTCBurstyDataBClpPktsTx2Line      OBJECT-TYPE
  SYNTAX    Counter
  ACCESS    read-only
  STATUS    mandatory
  DESCRIPTION    "The number of packets with the CLP bit set
       which have been transmitted onto the line
       from the bursty data B queue."
  ::=    { trunkRTCEntry 31 }

trunkRTCAtmCellHeaderHecErrors      OBJECT-TYPE
  SYNTAX    Counter
  ACCESS    read-only
  STATUS    mandatory
  DESCRIPTION    "The number of ATM cell headers with HEC
       errors."
  ::=    { trunkRTCEntry 32 }

trunkRTCTxVoiceCellsDropped      OBJECT-TYPE
  SYNTAX    Counter
  ACCESS    read-only
  STATUS    mandatory

  DESCRIPTION    "The number of transmit voice cells dropped."
  ::=    { trunkRTCEntry 33 }

trunkRTCTxTimeStampCellsDropped      OBJECT-TYPE
  SYNTAX    Counter
  ACCESS    read-only
  STATUS    mandatory
  DESCRIPTION    "The number of transmit time stamped cells
       dropped."
  ::=    { trunkRTCEntry 34 }

trunkRTCTxNonTStampCellsDropped      OBJECT-TYPE
  SYNTAX    Counter
  ACCESS    read-only
  STATUS    mandatory
  DESCRIPTION    "The number of transmit non time stamped cells
       dropped."
  ::=    { trunkRTCEntry 35 }

trunkRTCTxHighPriorityCellsDropped      OBJECT-TYPE
  SYNTAX    Counter
  ACCESS    read-only
  STATUS    mandatory
  DESCRIPTION    "The number of transmit high priority cells
       dropped."
  ::=    { trunkRTCEntry 36 }

trunkRTCTxBurstyDataACellsDropped      OBJECT-TYPE
  SYNTAX    Counter
  ACCESS    read-only
  STATUS    mandatory
  DESCRIPTION    "The number of cells dropped from the bursty 
       data A queue."
  ::=    { trunkRTCEntry 37 }

trunkRTCTxBurstyDataBCellsDropped      OBJECT-TYPE
  SYNTAX    Counter
  ACCESS    read-only
  STATUS    mandatory
  DESCRIPTION    "The number of cells dropped from the bursty 
       data B queue."
  ::=    { trunkRTCEntry 38 }

trunkRTCVoiceCellsTx2Line      OBJECT-TYPE
  SYNTAX    Counter
  ACCESS    read-only
  STATUS    mandatory
  DESCRIPTION    "The number of voice cells transmitted onto 
       the line."
  ::=    { trunkRTCEntry 39 }

trunkRTCTimeStampCellsTx2Line
      OBJECT-TYPE
  SYNTAX    Counter
  ACCESS    read-only
  STATUS    mandatory
  DESCRIPTION    "The number of time stamped cells transmitted
      onto the line."
  ::=    { trunkRTCEntry 40 }

trunkRTCNonTimeStampCellsTx2Line      OBJECT-TYPE
  SYNTAX    Counter
  ACCESS    read-only
  STATUS    mandatory
  DESCRIPTION    "The number of non time stamped cells

       transmitted onto the line."
  ::=    { trunkRTCEntry 41 }

trunkRTCHighPriorityCellsTx2Line      OBJECT-TYPE
  SYNTAX    Counter
  ACCESS    read-only
  STATUS    mandatory
  DESCRIPTION    "The number of high priority cells transmitted
       onto the line."
  ::=    { trunkRTCEntry 42 }

trunkRTCBurstyDataACellsTx2Line      OBJECT-TYPE
  SYNTAX    Counter
  ACCESS    read-only
  STATUS    mandatory
  DESCRIPTION    "The number of cells which have been
       transmitted onto the line from the bursty
       data A queue." 
      
  ::=    { trunkRTCEntry 43 }

trunkRTCBurstyDataBCellsTx2Line      OBJECT-TYPE
  SYNTAX    Counter
  ACCESS    read-only
  STATUS    mandatory
  DESCRIPTION    "The number of cells which have been
       transmitted onto the line from the bursty
       data B queue."
  ::=    { trunkRTCEntry 44 }

trunkRTCTotalCellsTx2Line      OBJECT-TYPE
  SYNTAX    Counter
  ACCESS    read-only
  STATUS    mandatory
  DESCRIPTION    "The number of cells transmitted onto the
       line."
  ::=    { trunkRTCEntry 45 }

trunkRTCTxBurstyDataAClpCellsDropped      OBJECT-TYPE
  SYNTAX    Counter
  ACCESS    read-only
  STATUS    mandatory
  DESCRIPTION    "The number of cells with the CLP bit set
      which have been dropped from the bursty 
      data A queue."
  ::=    { trunkRTCEntry 46 }

trunkRTCTxBurstyDataBClpCellsDropped      OBJECT-TYPE
  SYNTAX    Counter
  ACCESS    read-only
  STATUS    mandatory
  DESCRIPTION    "The number of cells with the CLP bit set
       which have been dropped from the bursty 
       data B queue."
  ::=    { trunkRTCEntry 47 }

trunkRTCBurstyDataAEfcnCellsTx2Line      OBJECT-TYPE
  SYNTAX    Counter
  ACCESS    read-only
  STATUS    mandatory
  DESCRIPTION    "The number of cells with the EFCN bit set 
       which have been transmitted onto the line 
       from the bursty data A queue."
  ::=    { trunkRTCEntry 48 }


trunkRTCBurstyDataBEfcnCellsTx2Line      OBJECT-TYPE
  SYNTAX    Counter
  ACCESS    read-only
  STATUS    mandatory
  DESCRIPTION    "The number of cells with the EFCN bit set
       which have been transmitted onto the line 
       from the bursty data B queue."
  ::=    { trunkRTCEntry 49 }

trunkRTCPlcpOutOfFrames      OBJECT-TYPE
  SYNTAX    Counter
  ACCESS    read-only
  STATUS    mandatory
  DESCRIPTION    "The number of out of frame conditions."
  ::=    { trunkRTCEntry 50 }


-- ---------------------------------------------------------
--  Trap Config Table
-- ---------------------------------------------------------

trapConfigTable      OBJECT-TYPE
  SYNTAX    SEQUENCE OF TrapConfigEntry
  ACCESS    not-accessible
  STATUS    mandatory
  DESCRIPTION    "The table has the information about the
       manager receiving traps"
  ::=    { trapsConfig 1 }

trapConfigEntry      OBJECT-TYPE
  SYNTAX    TrapConfigEntry
  ACCESS    not-accessible
  STATUS    mandatory
  DESCRIPTION    "An entry of the manager table."
  INDEX    { managerIPaddress }
  ::=    { trapConfigTable 1 }

TrapConfigEntry  ::=    SEQUENCE {
  managerIPaddress    IpAddress,
  managerPortNumber    INTEGER,
  managerRowStatus    INTEGER,
  readingTrapFlag    INTEGER,
  nextTrapSeqNum    INTEGER
}

managerIPaddress      OBJECT-TYPE
  SYNTAX    IpAddress
  ACCESS    read-write
  STATUS    mandatory
  DESCRIPTION  " "
  ::=    { trapConfigEntry 1 }

managerPortNumber      OBJECT-TYPE
  SYNTAX    INTEGER
  ACCESS    read-write
  STATUS    mandatory
  DESCRIPTION    " "
  ::=    { trapConfigEntry 2 }


managerRowStatus      OBJECT-TYPE
  SYNTAX    INTEGER  { 
        addRow  (1),
        delRow  (2)
        }

  ACCESS    read-write
  STATUS    mandatory
  DESCRIPTION    " "
  ::=    {  trapConfigEntry 3 }

readingTrapFlag      OBJECT-TYPE
  SYNTAX    INTEGER  { 
        false  (1),
        true  (2)
        }
  ACCESS    read-write
  STATUS    mandatory
  DESCRIPTION    " "
  ::=    { trapConfigEntry 4 }

nextTrapSeqNum      OBJECT-TYPE
  SYNTAX    INTEGER
  ACCESS    read-write
  STATUS    mandatory
  DESCRIPTION    " "
  ::=    { trapConfigEntry 5 }

managerNumOfValidEntries      OBJECT-TYPE
  SYNTAX    INTEGER(1..8)
  ACCESS    read-only
  STATUS    mandatory
  DESCRIPTION    "The number of managers in the table that are 
       programmed to receive traps"
  ::=    { trapsConfig 2 }


lastSequenceNumber      OBJECT-TYPE
  SYNTAX    INTEGER
  ACCESS    read-only
  STATUS    mandatory
  DESCRIPTION    "The Sequence Number of the last trap
       generated on the SNMP Proxy"
  ::=    { trapsConfig 3 }

-----------------------------------------------------------------------
--  RTM Group
--  
-----------------------------------------------------------------------


trapUploadTable      OBJECT-TYPE
  SYNTAX    SEQUENCE OF TrapUploadEntry
  ACCESS    not-accessible
  STATUS    mandatory
  DESCRIPTION    "The table has the information about the
       manager  receiving traps"
  ::=    { trapsConfig 4 }

trapUploadEntry      OBJECT-TYPE
  SYNTAX    TrapUploadEntry
  ACCESS    not-accessible
  STATUS    mandatory
  DESCRIPTION    "An entry of the manager table."
  INDEX    { mgrIpAddress }
  ::=    { trapUploadTable 1 }

TrapUploadEntry  ::=    SEQUENCE {
  mgrIpAddress    IpAddress,
  trapSequenceNum    INTEGER,
  trapPduString    OCTET STRING,

  endOfQueueFlag    INTEGER
}

mgrIpAddress      OBJECT-TYPE
  SYNTAX    IpAddress
  ACCESS    read-only
  STATUS    mandatory
  DESCRIPTION    " "
  ::=    { trapUploadEntry 1 }

trapSequenceNum      OBJECT-TYPE
  SYNTAX    INTEGER
  ACCESS    read-only
  STATUS    mandatory
  DESCRIPTION    "The sequence number associated with the trap"
  ::=    { trapUploadEntry 2 }

trapPduString      OBJECT-TYPE
  SYNTAX    OCTET STRING
  ACCESS    read-only
  STATUS    mandatory
  DESCRIPTION    "The sequence number associated with the trap"
  ::=    { trapUploadEntry 3 }

endOfQueueFlag      OBJECT-TYPE
  SYNTAX    INTEGER  {
        false(1),
        true(2)
        }
  ACCESS    read-only
  STATUS    mandatory
  DESCRIPTION    "The sequence number associated with the trap"
  ::=    { trapUploadEntry 4 }


--
--  control Group contains attributes associated with controlling
--  logGroup as a whole.  This group is mandatory

databaseSampleFreq      OBJECT-TYPE
  SYNTAX    INTEGER  (5..86400)
  ACCESS    read-write
  STATUS    mandatory
  DESCRIPTION    "The desired rate (in seconds) at which the
       database should be queried for new log
       records that match any of the filter criteria
       from the Event Filter Table.

       The agent may optionally poll more or less
       frequently then specified by this variable.
       The value of this variable is only a
       suggestion to the agent."
  DEFVAL    { 60 }
  ::=    { controlGroup 1 }


-----------------------------------------------------------------------
-- Log Group.
-----------------------------------------------------------------------

currentMaxLogIndex      OBJECT-TYPE
  SYNTAX    INTEGER
  ACCESS    read-only
  STATUS    mandatory
  DESCRIPTION    "The current max value of logIndex.  This

       value may change with time."
  ::=    { logGroup 1 }

-----------------------------------------------------------------------
--   Maint Log Table
-----------------------------------------------------------------------
maintLogTable      OBJECT-TYPE
  SYNTAX    SEQUENCE OF MaintLogEntry
  ACCESS    not-accessible
  STATUS    mandatory
  DESCRIPTION    "The table of log entries."
  ::=    { logGroup 2 }

maintLogEntry      OBJECT-TYPE
  SYNTAX    MaintLogEntry
  ACCESS    not-accessible
  STATUS    mandatory
  DESCRIPTION    "An entry in the log table."
  INDEX    { logIndex }
  ::=    { maintLogTable 1 }

MaintLogEntry  ::=    SEQUENCE {
  logIndex    INTEGER,
  logNetwork    DisplayString,
  logNodeName    DisplayString,
  logGmtDate    DisplayString,
  logSeverity    Severity,
  logMsg    DisplayString
      }

logIndex      OBJECT-TYPE
  SYNTAX    INTEGER  (1..1073741824)
  ACCESS    read-only
  STATUS    mandatory
  DESCRIPTION    "Unique index of the Log record."
  ::=    { maintLogEntry 1 }

logNetwork      OBJECT-TYPE
  SYNTAX    DisplayString (SIZE (0..10))
  ACCESS    read-only
  STATUS    mandatory
  DESCRIPTION    "Name of the network for which this log
       entry was generated."
  ::=    { maintLogEntry 2 }

logNodeName      OBJECT-TYPE
  SYNTAX    DisplayString (SIZE (0..10))
  ACCESS    read-only
  STATUS    mandatory
  DESCRIPTION    "Name of the IPX node for this log
       entry was generated."
  ::=    { maintLogEntry 3 }

logGmtDate      OBJECT-TYPE
  SYNTAX    DisplayString (SIZE (19))
  ACCESS    read-only
  STATUS    mandatory
  DESCRIPTION    "ASCII formatted string indicating the GMT
       date and time for this log record in the
       format (yyyy-mm-dd hh:mm:ss).  This is the
       time reported by the IPX which generated the
       event."
  ::=    { maintLogEntry 4 }

logSeverity      OBJECT-TYPE

  SYNTAX    Severity
  ACCESS    read-only
  STATUS    mandatory
  DESCRIPTION    "The severity of this log record."
  ::=    { maintLogEntry 5 }

logMsg      OBJECT-TYPE
  SYNTAX    DisplayString (SIZE (0..256))
  ACCESS    read-only
  STATUS    mandatory
  DESCRIPTION    "An ASCII message associated with this log
       record."
  ::=    { maintLogEntry 6 }

-----------------------------------------------------------------------
--  Event Filtering Table
-----------------------------------------------------------------------
--
--  In order for a manager to create a row of this table, a
--   single SET request should be sent with all the variables
--  for every column specified.
--
--  In order for a manager to delete a row of this table, a
--  single SET request should be sent to change the
--  eventFilterStatus column from 'active' to 'invalid'.
--
--  For a new log record to be forwarded as a TRAP the following
--  must be true:
--
--      eventFilterStatus     must be 'active'.
--
--      eventFilterSeverity   must exactly match the logSeverity
--      of the log record.
--
--      eventFilterSubstring  must contain a string that is
--      found in the logMsg variable of the
--      log record.
--
--  To request all events of all severity levels, set both the
--  eventFilterSeverity and eventFilterSubstring elements to
--  be zero-length strings.
--
eventFilterTable      OBJECT-TYPE
  SYNTAX    SEQUENCE OF EventFilterEntry
  ACCESS    not-accessible
  STATUS    mandatory
  DESCRIPTION    "The table of Event Filters."
  ::=    { logGroup 3 }

eventFilterEntry      OBJECT-TYPE
  SYNTAX    EventFilterEntry
  ACCESS    not-accessible
  STATUS    mandatory
  DESCRIPTION    "An entry in the Event Filter table.  Each
       entry in this table describes a set of log
       entry criteria, and entries in the log that
       match these criteria will be forwarded
       as SNMP TRAPS."
  INDEX    { eventFilterIndex }
  ::=    { eventFilterTable 1 }

EventFilterEntry  ::=     SEQUENCE {
  eventFilterIndex    INTEGER,
  eventFilterStatus    INTEGER,
  eventFilterSeverity    Severity,

  eventFilterSubstring    DisplayString }

eventFilterIndex      OBJECT-TYPE
  SYNTAX    INTEGER  ( 1 .. 2147483647)
  ACCESS    read-write
  STATUS    mandatory
  DESCRIPTION    "The unique index for each entry of this
       table. This entry can only be written with
       the first SET command to create a new row of
       this table."
  ::=    { eventFilterEntry 1 }

eventFilterStatus      OBJECT-TYPE
  SYNTAX    INTEGER  { invalid  (1),
          active  (2) }
  ACCESS    read-write
  STATUS    mandatory
  DESCRIPTION    "'active' indicates that this row of the table
       is currently generating filtered TRAPs.  When
       in this state, any entry added to the log
       table with logSeverity matching
       eventFilterSeverity and logMsg containing
       the eventFilterSubstring text, this
       information will be forwarded as a TRAP.

      'invalid' indicates that this row of the table
      is no longer generating filtered TRAPs.

      A conforming agent may either leave
      the row with the 'invalid' value in the table,
      or may delete the row from the table."
  DEFVAL    { active }
  ::=    { eventFilterEntry 2 }

eventFilterSeverity      OBJECT-TYPE
  SYNTAX    Severity
  ACCESS    read-write
  STATUS    mandatory
  DESCRIPTION    "The eventFilterSeverity specifies the
       severity of log records to be forwarded on
       as SNMP TRAPS by this event filter entry.
       The value of eventFilterSeverity must
       exactly match the value of logSeverity for
       there to be a chance that a new log record
       will be forwarded as a TRAP.
       An eventFilterSeverity of length 0 matches
       all severity levels."
  DEFVAL    { ''h }
  ::=    { eventFilterEntry 3 }

eventFilterSubstring      OBJECT-TYPE
  SYNTAX    DisplayString (SIZE (0..256))
  ACCESS    read-write
  STATUS    mandatory
  DESCRIPTION    "The eventFilterSubstring variable specifies
       an ASCII substring that must appear in the
       logMsg field of a log record in order for
       there to be a chance that for the log record
       to forwarded as a TRAP.  If this variable
       contains a zero length string, the substring
       comparison will always SUCCEED for this
       event filter entry."
  DEFVAL    { ''h }
  ::=    { eventFilterEntry 4 }


--
--  maintLog Table Filter Group
--
--  This group is optional and may be used to support filtering 
--  GetNext requests when retrieving elements from the 
--  mainLogTable.  If the group is supported then all attributes
--  in the group are mandatory.
--
--

maintLogFilterGroup      
  OBJECT IDENTIFIER ::= { logGroup 4 }

--  When applying the maintLogFilterGroup attributes during an
--  SNMP Operation, the order is important.  The attributes will
--  be applied in the following order:
--    maintLogFilterTimeMin
--    maintLogFilterTimeMax
--    maintLogFilterNetworkName
--    maintLogFilterNodeName
--    maintLogFilterSeverity
--    maintLogFilterWindow
--

maintLogFilterTimeMin      OBJECT-TYPE
  SYNTAX    DisplayString(SIZE(0..22))
  ACCESS    read-write
  STATUS    mandatory
  DESCRIPTION    "When maintLogFilterTimeMin has a value other
       than a 0 length string, the value is used as
       a minimum value for maintLogFilterGmtDate to
       qualify entries in the maintLogTable.

      The string is formatted as yyyy-mm-dd hh:mm:ss"
  DEFVAL    { ''h }
  ::=    { maintLogFilterGroup 1 }


maintLogFilterTimeMax      OBJECT-TYPE
  SYNTAX    DisplayString(SIZE(0..22)) 
  ACCESS    read-write
  STATUS    mandatory
  DESCRIPTION    "When maintLogFilterTimeMax has a value other
       than a 0 length string, the value is used as
       a maximum value for maintLogFilterGmtDate to
       qualify entries in the maintLogTable.

      The string is formatted as yyyy-mm-dd hh:mm:ss"
  DEFVAL    { ''h }
  ::=    { maintLogFilterGroup 2 }

maintLogFilterWindow      OBJECT-TYPE
  SYNTAX    INTEGER
  ACCESS    read-write
  STATUS    mandatory
  DESCRIPTION    "When maintLogFilterWindow has a value other
       than 0, the value is used to qualify entries
       in the maintLogTable.

       This attribute has the effect of limiting the 
       view in the maintLogTable to the number
       specified by the value of this attribute.

       If after applying the other maintLogFilter
       attributes, the remaining set exceeds the

       value of maintLogFilterWindow then, the set
       of entries which can be viewed is limited to
       the  top N based on the logIndex value."
  DEFVAL    { 30 }
  ::=             { maintLogFilterGroup 3 }

maintLogFilterNetworkNam      OBJECT-TYPE
  SYNTAX    DisplayString (SIZE (0..10)) 
  ACCESS    read-write
  STATUS    mandatory
  DESCRIPTION    "When maintLogFilterNetworkName has a value
       other than a 0 length string, then the value
       of this attribute is used to qualify entries
       in the maintLogTable.  This value must match
       logNetwork exactly to pass the filter."
  DEFVAL    { ''h }
  ::=    { maintLogFilterGroup 4 }

maintLogFilterNodeName      OBJECT-TYPE
  SYNTAX    DisplayString (SIZE (0..10)) 
  ACCESS    read-write
  STATUS    mandatory
  DESCRIPTION    "When maintLogFilterNodeName has a value other
      than a 0 length string, then the value of this
      attribute is used to qualify entries in the
      maintLogTable.  This value must match logNodeName
      exactly to pass the filter."
  DEFVAL    { ''h }
  ::=    { maintLogFilterGroup 5 }

maintLogFilterSeverity      OBJECT-TYPE
  SYNTAX    Severity 
  ACCESS    read-write
  STATUS    mandatory
  DESCRIPTION    "When maintLogFilterSeverity has a value other
      than a 0 length string, then the value is used
      to qualify entries in the maintLogTable.  The
      value must match the logSeverity exactly to 
      pass the filter."
  DEFVAL    { ''h }
  ::=    { maintLogFilterGroup 6 }

-----------------------------------------------------------------------
--  Network Group
-----------------------------------------------------------------------

-----------------------------------------------------------------------
--  Network Table
-----------------------------------------------------------------------
networkTable      OBJECT-TYPE
  SYNTAX    SEQUENCE OF NetworkEntry
  ACCESS    not-accessible
  STATUS    mandatory
  DESCRIPTION    "The table of Networks."
  ::=    { networkGroup 1 }

networkEntry      OBJECT-TYPE
  SYNTAX    NetworkEntry
  ACCESS    not-accessible
  STATUS    mandatory
  DESCRIPTION    "An entry in the Network table."
  INDEX    { networkName }
  ::=    { networkTable 1 }

NetworkEntry  ::=  SEQUENCE {

  networkName  DisplayString,
  networkId  INTEGER,
  networkIpxId  INTEGER
}

networkName      OBJECT-TYPE
  SYNTAX    DisplayString (SIZE(0..10))
  ACCESS    read-only
  STATUS    mandatory
  DESCRIPTION    "The name of the network as assigned by
      the StrataView User."
  ::=    { networkEntry 1 }

networkId      OBJECT-TYPE
  SYNTAX    INTEGER
  ACCESS    read-only
  STATUS    mandatory
  DESCRIPTION    "The unique ID of the network as assigned
      by the StrataView system."
  ::=    { networkEntry 2 }

networkIpxId      OBJECT-TYPE
  SYNTAX    INTEGER
  ACCESS    read-only
  STATUS    mandatory
  DESCRIPTION    "The IPX network ID."
  ::=    { networkEntry 3 }

-----------------------------------------------------------------------
--  Node Group
-----------------------------------------------------------------------

-----------------------------------------------------------------------
--  Node Table
-----------------------------------------------------------------------
nodeTable      OBJECT-TYPE
  SYNTAX    SEQUENCE OF NodeEntry
  ACCESS    not-accessible
  STATUS    mandatory
  DESCRIPTION    "The table of Nodes."
  ::=    { nodeGroup 1 }

nodeEntry      OBJECT-TYPE
  SYNTAX    NodeEntry
  ACCESS    not-accessible
  STATUS    mandatory
  DESCRIPTION    "An entry in the Node table."
  INDEX    { nodeNetworkName, nodeName }
  ::=    { nodeTable 1 }

NodeEntry  ::=    SEQUENCE {
  nodeNetworkName    DisplayString,
  nodeName    DisplayString
}

nodeNetworkName      OBJECT-TYPE
  SYNTAX    DisplayString (SIZE (0..10))
  ACCESS    read-only
  STATUS    mandatory
  DESCRIPTION    "The name of the network to which this node is
       attached."
  ::=    { nodeEntry 1 }

nodeName      OBJECT-TYPE
  SYNTAX    DisplayString (SIZE(0..10))

  ACCESS    read-only
  STATUS    mandatory
  DESCRIPTION    "IPX node name."
  ::=    { nodeEntry 2 }

-- 
--      Trap Definitions
-- 

trunkStatusAlarm             TRAP-TYPE
  ENTERPRISE          svnode
  VARIABLES           {       
      lastSequenceNumber,
      nodeGrpName,
      nodeGrpNetName,
      trunkStatus
      }
  DESCRIPTION         "This trap is generated whenever an
       ObjectAlarm Status message is received
       containing the trunk status."
        ::= 0

cirLineStatusAlarm      TRAP-TYPE
  ENTERPRISE    svnode
  VARIABLES           {
      lastSequenceNumber,
      nodeGrpName,
      nodeGrpNetName,
      cirLineStatus
      }
  DESCRIPTION    "This trap is generated whenever an
       ObjectAlarm Status message is received
       containing the cirLineStatus."
  ::= 1

frpStatusAlarm      TRAP-TYPE
  ENTERPRISE    svnode
  VARIABLES    {       
      lastSequenceNumber,
      nodeGrpName,
      nodeGrpNetName,
      frpStatus
      }
  DESCRIPTION    "This trap is generated whenever an
       ObjectAlarm Status message is received
       containing the frpStatus."
  ::= 2

connStatusAlarm           TRAP-TYPE
  ENTERPRISE      svnode
  VARIABLES    {       
      lastSequenceNumber,
      nodeGrpName,
      nodeGrpNetName,
      connStatus,
      connABitStatus
      }
        DESCRIPTION      "This trap is generated whenever an
       ObjectAlarm Status message is received
       containing the connStatus."
        ::= 3


filteredLogRecord      TRAP-TYPE
  ENTERPRISE    svplus

  VARIABLES    {   
      lastSequenceNumber,
      logIndex,
      logNetwork,
      logNodeName,
      logGmtDate,
      logSeverity,
      logMsg
      }
  DESCRIPTION    "The 'filteredLogRecord' trap is generated by
      the StrataView system whenever an entry in the
      eventFilterTable matches a log record that is
      added to the StrataView database."
  ::= 0