cc/td/doc/cisintwk
hometocprevnextglossaryfeedbacksearchhelp
PDF

Table of Contents

SNA Host Configuration for SDLC Networks

SNA Host Configuration for SDLC Networks

This appendix outlines router implementation information related to the following topics:

Table D-1 outlines 3x74 SDLC point-to-point connection support for AGS+, MGS, and CGS DCE appliques.


Table  D-1: 3x74 SDLC Point-to-Point Connection Support for AGS+, MGS, and CGS DCE Appliques
Controller Type RS-232 DCE RS-232 NRZI/DCE
3274 1st Generation

  • 3274-1C


Supported


Supported

3274 2nd Generation

  • 3274-21C


Not tested


Supported

3274 3rd Generation

  • 3274-31C

  • 3274-51C


Supported

Supported


Not tested

Not tested

3274 4th Generation

  • 3274-41C

  • 3274-61C

  • Telex 274

  • Telex 1274

Need to tie DSR and DTR together on CU side, break DSR to router


Same as 3274-41C

Supported

Supported

Not tested


Supported

Not tested

Not tested

DCA/IRMA 3274 emulation for DOS workstations

DEC SNA gateway

RS 6000 multiprotocol adapter

Not tested


Not tested

Not tested

Supported


Supported

Supported

3174 Subsystem CUs

  • 3174-01R



  • 3174-03R

  • 3174-51R


Not tested



Same as 3174-01R

Same as 3174-01R

3174 ties pin 11 low, (-11VDC) which forces the applique into DTE mode (DCE mode is set when pin 11 is set high)

Same as 3174-01R

Same as 3174-01R

3174 Establishment CUs

  • 3174-11R

  • 3174-13R

  • 3174-61R

  • 3174-91R

  • Telex 1174


Not tested

Same as 3174-11R

Same as 3174-11R

Same as 3174-11R

Supported


Supported

Not tested

Not tested

Supported

Not tested

FEP Configuration for SDLC Links

Table D-2 through Table D-5 present relevant parameter definitions for an FEP configured to operate within a router-based environment. These parameters are configured as part of the system generation process associated with the Network Control Program (NCP) on an IBM host.


Table  D-2: FEP SDLC Configuration Sample GROUP Parameter Listing and Definitions
Parameter Sample Value Description and Implementation Notes
LNCTL SDLC Line control parameter that specifies link protocol
REPLYTO 2 T1 timer; this timer specifies the reply timeout value for LINEs in this GROUP

Table  D-3: FEP SDLC Configuration Sample LINE Parameter Listing and Definitions
Parameter Sample Value Description and Implementation Notes
ADDRESS (001,HALF) The value 001 is the physical LINE interface address of the FEP. The second parameter specifies whether half- or full-duplex data transfer within the FEP is used. It also effects the DUPLEX parameter: If FULL is specified here, DUPLEX defaults to FULL and attempts to modify this characteristic are ignored.
DUPLEX HALF This parameter specifies whether the communication line and modem constitute a half-duplex or full-duplex facility. If HALF is specified, the RTS modem signal is activated only when sending data. If FULL is specified, RTS always remains active. Refer to the ADDRESS parameter in this table.
NRZI YES Encoding for this line; options are NRZ or NRZI.
RETRIES (6,5,3) Number of retries when REPLYTO expires. Entry options: (m, t, n) where m = number of retries, t = pause in seconds between retry cycles, and n = number of retry cycles to repeat. This example would retry 6 times--pausing the value of the REPLYTO between each RETRY (2 seconds per Table D-2), pause 5 seconds, and repeat this sequence 3 times for a total of 63 seconds. At the end of this period, the session is terminated.
PAUSE 2 The delay time in milliseconds between poll cycles. The cycle extends from the time NCP polls the first entry in the service order table to the moment polling next begins at the same entry. During this pause, any data available to send to the end station is sent. If end stations have data to send when polled, and the time to send the data extends beyond the PAUSE parameter, the next poll cycle begins immediately.

Table  D-4: FEP SDLC Configuration Sample PU Parameter Listing and Definitions
Parameter Sample Value Description and Implementation Notes
ADDR C1 SDLC address of secondary end station
MAXDATA 265 Maximum amount of data in bytes (including headers) that the UP can receive in one data transfer; that is, one entire PIU or a PIU segment
MAXOUT 7 Maximum number of unacknowledged frames that NCP can have outstanding before requesting a response from the end station
PASSLIM 7 Maximum number of consecutive PIU or PIU segments that NCP sends at one time to the end station represented by this PU definition
PUTYPE 2 Specifies PU type; PU type 2 and 2.1 are both specified as PUTYPE=2

Table  D-5: FEP SDLC Configuration Sample LU Parameter Listing and Definitions
Parameter Sample Value Description and Implementation Notes
LOCADDR 2 LU address of devices connected to the end station PU.

3174 SDLC Configuration Worksheet

Table D-6 through Table D-8 present a configuration taken from an SDLC-connected 3174-91R cluster controller. The configuration of this 3174-91R involved three specific configuration screens. Table D-6 through Table D-8 list the configuration line numbers, entries used, and descriptions of the configuration lines for each screen. Where applicable, extended descriptions are included for configuration entries that are relevant to the requirements of the routed internetwork.


Table  D-6: 3174-91R Screen 1 Configuration Details
Configuration Line
Number

Sample Value

Parameter Description and Implementation Notes
98 Online test password
99 TKNRNG Description field
100 91R Model number
101 2 Host attachment type:

  • 2 = SDLC

  • 5 = SNA (channel-attached)

  • 7 = Token Ring network


Note Configuration line items 104, 313, 317, 340, and 340 in Configuration screen 2 (refer to
Table D-7) are of particular interest when configuring 3174 devices for a router-based SDLC environment. These lines specify the required SDLC address and relevant SDLC options for the cluster controller.

Table  D-7: 3174-91R Screen 2 Configuration Details
Configuration Line
Number

Sample Value

Parameter Description and Implementation Notes
104 C2 Specifies the cluster controller SDLC address. It is the same address that you configure on the router's serial line interface. It also represents the PU address of the controller. In multipoint environments, multiple SDLC addresses may be specified on a single serial interface.
108 0045448 Serial number of the cluster controller
110 0 MLT storage support
116 0 Individual port assignment
121 01 Keyboard language
123 0 Country extended code page support
125 00000000 Miscellaneous options (A)
126 00000000 Miscellaneous options (B)
127 0 0 RTM definition
132 0000 Alternate base keyboard selection
136 0000 Standard keyboard layout
137 0000 Modified keyboard layout
138 0 Standard keypad layout
141 A Magnetic character set
150 0 Token Ring network gateway controller
165 0 Compressed program symbols
166 A Attribute select keypad
168 0 Additional extension; mode key definition
173 0000 DFT options
175 000000 DFT password
179 000 Local format storage
213 0 Between-bracket printer sharing
215 45448 PU identification
220 0 Alert function
310 0 Connect dataset to line operation
313 0 NRZ = 0; NRZI = 1
317 0 Telecommunications facility:

  • 0 = Nonswitched

  • 1 = Switched (dial-up)

318

0 Full/half speed transmission; 0 = full speed, 1 = half speed. Controls speed of modem; can be used in areas where line conditions are poor
340 0 RTS control options:

  • 0 = Controlled RTS (for LSD/MSD operation)

  • 1 = Permanent RTS (improves performance)

  • 2 = BSC (not valid for SDLC operation)

365

0 X.21 switched-host DTE connection
370 0 Maximum inbound I-frame size:

  • 0 = 265 bytes

  • 1 = 521 bytes (recommended for better performance)


Table  D-8: 3174-91R Screen 3 Configuration Details
Configuration Line
Number

Sample Value

Parameter Description and Implementation Notes
500 0 Central Site Change Management (CSCM) unique
501 xxxxxxxx Network identifier
503 xxxxxxxx LU name (for CSCM)

hometocprevnextglossaryfeedbacksearchhelp
Copyright 1989-1997 © Cisco Systems Inc.